- M Menzel, A Rieger, S Roth, L Sanchin, J Soukup, C Hennig, H Furka, W Burkert, and J Radke.
- Klinik für Anästhesie und Intensivmedizin der Martin-Luther-Universität Halle-Wittenberg.
- Anaesthesist. 1997 Feb 1;46(2):108-13.
UnlabelledThe reliability of continuous fibreoptic oximetry in cerebral venous blood and its correlation with intracranial and cerebral perfusion pressures (pressure-volume curve) were examined in an experimental porcine study.MethodsThe pressure in the infratentorial compartment of 13 domestic pigs (18-24 kg) was gradually increased by inflating a Fogarty balloon catheter placed on the surface of the right cerebellar hemisphere and below the tentorium. Single volumes of 0.4 ml saline were injected into the inflatable balloon at 1-min intervals up to a total volume of 7 ml. Intracranial pressure (ICP), arterial blood pressure, cerebral perfusion pressure (CPP), and cerebral venous saturation measured continuously by fibreoptic oximetry and intermittent blood-gas analyses (SjO2 superior sagittal sinus) were monitored during balloon inflation. All data were down-loaded onto a PC and evaluated off-line by a commercial statistical software package.ResultsOver the whole pressure-volume curve, two phases of SjO2 behaviour were registered by continuous fibreoptic oximetry (Oximetrix 3, Abbott) (Fig. 1). CPP ranges of less than 50% reduction from the initial value showed a linear correlation (rmittl. = 0.712, P < 0.01) between both parameters (CPP-SjO2). In CPP ranges below a crucial point of about 50 mmHg no such correlation was found (rmittl = 0.176, P < 0.5). In contrast, in 3 pigs a very good correlation was found between CPP and SjO2 over the whole pressure-volume curve as measured by blood-gas analyses of samples from the cerebrovenous catheter (rmittl. = 0.84, P < 0.05).DiscussionWe conclude that in physiological CPP ranges down to 50 mmHg, SjO2 measurement is a reliable method of detecting oxygen desaturation in cerebrovenous blood. Below that CPP value, the fibreoptic catheter showed repeated false-high oxygen saturation values. The accuracy of SjO2 measurement seems to depend on sufficient cerebral blood flow (CBF): with decreasing CBF the amount of cerebral venous outflow is diminished. We believe this is why we could not find a correlation in low CPP ranges with the oximetry catheter. This flow-dependency is a new aspect of fibreoptic cerebrovenous oximetry. The authors recommend that rising SjO2 values after desaturation events be confirmed by blood-gas analyses.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.