• Der Anaesthesist · Feb 1997

    [Cerebrovascular fiberoptic catheter oximetry in an intracranial pressure model in swine. New aspects of a clinical routine].

    • M Menzel, A Rieger, S Roth, L Sanchin, J Soukup, C Hennig, H Furka, W Burkert, and J Radke.
    • Klinik für Anästhesie und Intensivmedizin der Martin-Luther-Universität Halle-Wittenberg.
    • Anaesthesist. 1997 Feb 1;46(2):108-13.

    UnlabelledThe reliability of continuous fibreoptic oximetry in cerebral venous blood and its correlation with intracranial and cerebral perfusion pressures (pressure-volume curve) were examined in an experimental porcine study.MethodsThe pressure in the infratentorial compartment of 13 domestic pigs (18-24 kg) was gradually increased by inflating a Fogarty balloon catheter placed on the surface of the right cerebellar hemisphere and below the tentorium. Single volumes of 0.4 ml saline were injected into the inflatable balloon at 1-min intervals up to a total volume of 7 ml. Intracranial pressure (ICP), arterial blood pressure, cerebral perfusion pressure (CPP), and cerebral venous saturation measured continuously by fibreoptic oximetry and intermittent blood-gas analyses (SjO2 superior sagittal sinus) were monitored during balloon inflation. All data were down-loaded onto a PC and evaluated off-line by a commercial statistical software package.ResultsOver the whole pressure-volume curve, two phases of SjO2 behaviour were registered by continuous fibreoptic oximetry (Oximetrix 3, Abbott) (Fig. 1). CPP ranges of less than 50% reduction from the initial value showed a linear correlation (rmittl. = 0.712, P < 0.01) between both parameters (CPP-SjO2). In CPP ranges below a crucial point of about 50 mmHg no such correlation was found (rmittl = 0.176, P < 0.5). In contrast, in 3 pigs a very good correlation was found between CPP and SjO2 over the whole pressure-volume curve as measured by blood-gas analyses of samples from the cerebrovenous catheter (rmittl. = 0.84, P < 0.05).DiscussionWe conclude that in physiological CPP ranges down to 50 mmHg, SjO2 measurement is a reliable method of detecting oxygen desaturation in cerebrovenous blood. Below that CPP value, the fibreoptic catheter showed repeated false-high oxygen saturation values. The accuracy of SjO2 measurement seems to depend on sufficient cerebral blood flow (CBF): with decreasing CBF the amount of cerebral venous outflow is diminished. We believe this is why we could not find a correlation in low CPP ranges with the oximetry catheter. This flow-dependency is a new aspect of fibreoptic cerebrovenous oximetry. The authors recommend that rising SjO2 values after desaturation events be confirmed by blood-gas analyses.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…