• J. Thromb. Haemost. · Feb 2007

    Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

    • L Rugeri, A Levrat, J S David, E Delecroix, B Floccard, A Gros, B Allaouchiche, and C Negrier.
    • Laboratory of Haemostasis, Edouard Herriot Hospital, Hospices Civils de Lyon and Claude Bernard University, Lyon, France. lucia.rugeri@chu-lyon.fr
    • J. Thromb. Haemost. 2007 Feb 1;5(2):289-95.

    BackgroundReagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma.ObjectivesThe goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion.MethodsNinety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM).ResultsTrauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively.ConclusionsROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.