• Am. J. Obstet. Gynecol. · Nov 1997

    Multicenter Study

    Multicenter study on the clinical value of fetal pulse oximetry. I. Methodologic evaluation. The French Study Group on Fetal Pulse Oximetry.

    • F Goffinet, B Langer, B Carbonne, N Berkane, D Tardif, F Le Goueff, M Laville, and F Maillard.
    • Institut National de la Santé et de la Recherche Médicale U 149, Paris, France.
    • Am. J. Obstet. Gynecol. 1997 Nov 1;177(5):1238-46.

    ObjectiveOur purpose was to evaluate the feasibility of intrapartum fetal pulse oximetry, the distribution of fetal oxygen saturation values, and the relationship with the neonatal outcome in a population with an abnormal fetal heart rate.Study DesignA prospective multicenter observational study was performed from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded with use of a Nellcor N-400 fetal pulse oximeter in case of an abnormal fetal heart rate during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis were obtained at inclusion and before birth. Feasibility, adverse effects, distribution of fetal oxygen saturation values, and relationship with neonatal outcome were assessed.ResultsOne hundred seventy-four patients were included. From 172 attempted sensor placements, the procedure was impossible in three cases and fetal oxygen saturation values were obtained in 164 cases (95.3%). Physicians considered sensor placement an easier task than an attempt at fetal blood analysis (easy in 87.5% vs 78.9% for fetal blood analysis, p = 0.03). The mean reliable signal time (+/- SD) was 64.7% +/- 32% during the first stage. There were no serious adverse effects in the study population. The mean fetal oxygen saturation during the first stage of labor was 42.2% +/- 8.0% (10th to 90th percentile range 30% to 53%). Fetal oxygen saturation was significantly correlated with scalp pH (r = 0.29, p = 0.01) but not with neonatal umbilical artery pH or gas values. There was a significant association between low fetal oxygen saturation (< 30%) and poor neonatal condition.ConclusionThe feasibility of fetal pulse oximetry is satisfactory in clinical practice. It is easy to use and provides a fair rate of recorded values, even in a population with suspicion of fetal distress. A low fetal oxygen saturation is significantly associated with an abnormal neonatal outcome.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.