• Crit Care · Jan 2013

    Multicenter Study

    An investigation of sound levels on intensive care units with reference to the WHO guidelines.

    • Julie L Darbyshire and J Duncan Young.
    • Crit Care. 2013 Jan 1;17(5):R187.

    IntroductionPatients in intensive care units (ICUs) suffer from sleep deprivation arising from nursing interventions and ambient noise. This may exacerbate confusion and ICU-related delirium. The World Health Organization (WHO) suggests that average hospital sound levels should not exceed 35 dB with a maximum of 40 dB overnight. We monitored five ICUs to check compliance with these guidelines.MethodsSound levels were recorded in five adult ICUs in the UK. Two sound level monitors recorded concurrently for 24 hours at the ICU central stations and adjacent to patients. Sample values to determine levels generated by equipment and external noise were also recorded in an empty ICU side room.ResultsAverage sound levels always exceeded 45 dBA and for 50% of the time exceeded between 52 and 59 dBA in individual ICUs. There was diurnal variation with values decreasing after evening handovers to an overnight average minimum of 51 dBA at 4 AM. Peaks above 85 dBA occurred at all sites, up to 16 times per hour overnight and more frequently during the day. WHO guidelines on sound levels could be only achieved in a side room by switching all equipment off.ConclusionAll ICUs had sound levels greater than WHO recommendations, but the WHO recommended levels are so low they are not achievable in an ICU. Levels adjacent to patients are higher than those recorded at central stations. Unit-wide noise reduction programmes or mechanical means of isolating patients from ambient noise, such as earplugs, should be considered.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…