- Lisette P van der Vight, Emile N J Th van Lin, Ilse Spitters-Post, Andries G Visser, and Robert J W Louwe.
- Radboud University Nijmegen Medical Centre, Department of Radiation Oncology, The Netherlands.
- Radiother Oncol. 2009 Mar 1;90(3):359-66.
PurposeTo evaluate the efficiency of combining on-line and off-line corrections for the positioning of patients receiving external beam radiotherapy for prostate cancer.Materials And MethodsDaily portal images were acquired during the treatment of 102 patients to verify and correct the position of the prostatic gland using implanted gold markers. In addition to an existing off-line procedure, on-line corrections were applied in the anterior-posterior (AP) direction only, to limit the increase in daily workload. The possible increase in workload of the combined correction procedure for on-line corrections in either two or three directions was further investigated by simulating the required position corrections for 500 treatments.ResultsThe combined correction procedure in AP-direction resulted in a systematic dispersion and random variation of 0.3mm (1 SD) and 1.0mm (1 SD), respectively. Application of off-line corrections during pre-treatment setup reduced the number of required on-line corrections from 22+/-4 (1 SD) to 17+/-4 (1 SD), at the cost of 1.4+/-1.0 (1 SD) off-line corrections. For on-line corrections in two or three directions, application of a combined on-line/off-line procedure did not noticeably reduce the number of setup corrections.ConclusionsThe on-line procedure is feasible and significantly improves both systematic and random errors to below 1 mm with a limited impact on the workload and treatment time. The application of off-line setup corrections during pre-treatment patient positioning only marginally reduces the number of on-line setup corrections.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.