• Indian J Crit Care Med · May 2014

    Apnea testing with continuous positive airway pressure for the diagnosis of brain death in a patient with poor baseline oxygenation status.

    • Gentle Sunder Shrestha, Pramesh Sunder Shrestha, Subhash Prasad Acharya, Gopal Sedain, Sandip Bhandari, Diptesh Aryal, Bikram Gajurel, Moda Nath Marhatta, and Roshana Amatya.
    • Department of Anaesthesiology, Institute of Medicine, Tribhuvan University Teaching Hospital, Maharajgunj, Kathmandu, Nepal.
    • Indian J Crit Care Med. 2014 May 1;18(5):331-3.

    AbstractApnea testing is a key component in the clinical diagnosis of brain death. Patients with poor baseline oxygenation may not tolerate the standard 8-10 min apnea testing with oxygen insufflation through tracheal tube. No studies have assessed the safety and feasibility of other methods of oxygenation during apnea testing in these types of patients. Here, we safely performed apnea testing in a patient with baseline PaO2 of 99.1 mm Hg at 100% oxygen. We used continuous positive airway pressure (CPAP) of 10 cm of H2O and 100% oxygen at the flow rate of 12 L/min using the circle system of anesthesia machine. After 10 min of apnea testing, PaO2 decreased to 75.7 mm Hg. There was a significant rise in PaCO2 and fall in pH, but without hemodynamic instability, arrhythmias, or desaturation. Thus, the apnea test was declared positive. CPAP can be a valuable, feasible and safe means of oxygenation during apnea testing in patients with poor baseline oxygenation, thus avoiding the need for ancillary tests.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…