• Int J Stroke · Jul 2014

    Randomized Controlled Trial Multicenter Study Comparative Study

    SOLITAIRE™ with the intention for thrombectomy (SWIFT) trial: design of a randomized, controlled, multicenter study comparing the SOLITAIRE™ Flow Restoration device and the MERCI Retriever in acute ischaemic stroke.

    • J L Saver, R Jahan, E I Levy, T G Jovin, B Baxter, R Nogueira, W Clark, R Budzik, O O Zaidat, and SWIFT Trialists.
    • Department of Neurology and Stroke Center, UCLA, Los Angeles, California, USA.
    • Int J Stroke. 2014 Jul 1;9(5):658-68.

    RationaleSelf-expanding stent retrievers are a promising new device class designed for rapid flow restoration in acute cerebral ischaemia. The SOLITAIRE™ Flow Restoration device (SOLITAIRE) has shown high rates of recanalization in preclinical models and in uncontrolled clinical series.Aims(1) To demonstrate non-inferiority of SOLITAIRE compared with a legally marketed device, the MERCI Retrieval System®; (2) To demonstrate safety, feasibility, and efficacy of SOLITAIRE in subjects requiring mechanical thrombectomy diagnosed with acute ischaemic stroke. DESIGN : Multicenter, randomized, prospective, controlled trial with blinded primary end-point ascertainment.Study ProceduresKey entry criteria include: age 22-85; National Institute of Health Stroke Scale (NIHSS) ≥8 and <30; clinical and imaging findings consistent with acute ischaemic stroke; patient ineligible or failed intravenous tissue plasminogen activator; accessible occlusion in M1 or M2 middle cerebral artery, internal carotid artery, basilar artery, or vertebral artery; and patient able to be treated within 8 h of onset. Sites first participate in a roll-in phase, treating two patients with the SOLITAIRE device, before proceeding to the randomized phase. In patients unresponsive to the initially assigned therapy, after the angiographic component of the primary end-point is ascertained (reperfusion with the initial assigned device), rescue therapy with other reperfusion techniques is permitted.OutcomesThe primary efficacy end-point is successful recanalization with the assigned study device (no use of rescue therapy) and with no symptomatic intracranial haemorrhage. Successful recanalization is defined as achieving Thrombolysis In Myocardial Ischemia 2 or 3 flow in all treatable vessels. The primary safety end-point is the incidence of device-related and procedure-related serious adverse events. A major secondary efficacy end-point is time to achieve initial recanalization. Additional secondary end-points include clinical outcomes at 90 days and radiologic haemorrhagic transformation.© 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…