    Accuracy of end-tidal carbon dioxide monitoring using the NBP-75 microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patients.

    • A Casati, G Gallioli, M Scandroglio, R Passaretta, B Borghi, and G Torri.
    • Department of Anaesthesiology, University of Milan, IRCCS H. San Raffaele, via Olgettina 60, 20132 Milan, Italy.
    • Eur J Anaesthesiol. 2000 Oct 1;17(10):622-6.

    AbstractArterial carbon dioxide partial pressure measurements using the NBP-75 microstream capnometer were compared with direct PaCO2 values in patients who were (a) not intubated and spontaneously breathing, and (b) patients receiving intermittent positive pressure ventilation of the lungs and endotracheal anaesthesia. Twenty ASA physical status I-III patients, undergoing general anaesthesia for orthopaedic or vascular surgery were included in a prospective crossover study. After a 20-min equilibration period following the induction of general anaesthesia, arterial blood was drawn from an indwelling radial catheter, while the end-tidal carbon dioxide partial pressure was measured at the angle between the tracheal tube and the ventilation circuit using a microstream capnometer (NBP-75, Nellcor Puritan Bennett, Plesanton, CA, USA) with an aspiration flow rate of 30 mL min(-1). Patients were extubated at the end of surgery and transferred to the postanaesthesia care unit, where end-tidal carbon dioxide was sampled through a nasal cannula (Nasal FilterLine, Nellcor, Plesanton, CA, USA) and measured using the same microstream capnometer. In each patient six measurements were performed, three during mechanical ventilation and three during spontaneous breathing. A good correlation between arterial and end-tidal carbon dioxide partial pressure was observed both during mechanical ventilation (r = 0.59; P = 0.0005) and spontaneous breathing (r = 0.41; P = 0.001); while no differences in the arterial to end-tidal carbon dioxide tension difference were observed when patients were intubated and mechanically ventilated (7. 3 +/- 4 mmHg; CI95: 6.3-8.4) compared to values measured during spontaneous breathing in the postanesthesia care unit, after patients had been awakened and extubated (6.5 +/- 4.8 mmHg; CI95: 5. 2-7.8) (P = 0.311). The mean difference between the arterial to end-tidal carbon dioxide tension gradient measured in intubated and non-intubated spontaneously breathing patients was 1 +/- 6 mmHg (CI95: -11-+13). We conclude that measuring the end-tidal carbon dioxide partial pressure through a nasal cannula using the NBP-75 microstream capnometer provides an estimation of arterial carbon dioxide partial pressure similar to that provided when the same patients are intubated and mechanically ventilated.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…