• Indian J Anaesth · Dec 2009

    Patient Controlled Epidural Analgesia during Labour: Effect of Addition of Background Infusion on Quality of Analgesia & Maternal Satisfaction.

    • Uma Srivastava, Amrita Gupta, Surekha Saxena, Aditya Kumar, Saroj Singh, Namita Saraswat, Abhijeet R Mishra, Ashish Kannaujia, and Sukhdev Mishra.
    • Professor, Research scholar Agra University.
    • Indian J Anaesth. 2009 Dec 1;53(6):649-53.

    AbstractPatient controlled epidural analgesia (PCEA) is a well established technique for pain relief during labor. But the inclusion of continuous background infusion to PCEA is controversial. The aim of this study was to assess whether the use of continuous infusion along with PCEA was beneficial for laboring women with regards to quality of analgesia, maternal satisfaction and neonatal outcome in comparison to PCEA alone. Fifty five parturients received epidural bolus of 10ml solution containing 0.125% bupivacaine +2 microg.ml(-1) of fentanyl. For maintenance of analgesia the patients of Group PCEA self administered 8 ml bolus with lockout interval of 20 minutes of above solution on demand with no basal infusion. While the patients of Group PCEA + CI received continuous epidural infusion at the rate of 10 ml.hr-1 along with self administered boluses of 3 ml with lockout interval of 10 minutes of similar epidural solution. Patients of both groups were given rescue boluses by the anaesthetists for distressing pain. Verbal analogue pain scores, incidence of distressing pain, need of supplementary/rescue boluses, dose of bupivacaine consumed, maternal satisfaction and neonatal Apgar scores were recorded. No significant difference was observed between mean VAS pain scores during labor, maternal satisfaction, mode of delivery or neonatal Apgar scores. But more patients (n=8) required rescue boluses in PCEA group for distressing pain. The total volume consumed of bupivacaine and opioid was slightly more in PCEA + CI group. In both the techniques the highest sensory level, degree of motor block were comparable & prolongation of labor was not seen. It was concluded that both the techniques provided equivalent labor analgesia, maternal satisfaction and neonatal Apgar scores. PCEA along with continuous infusion at the rate of 10 ml/ hr resulted in lesser incidence of distressing pain and need for rescue analgesic. Although this group consumed higher dose of bupivacaine, it did not affect maternal or neonatal safety.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…