• J Bone Joint Surg Am · Sep 2012

    Comparative Study

    Revision for unexplained pain following unicompartmental and total knee replacement.

    • Paul N Baker, Timothy Petheram, Peter J Avery, Paul J Gregg, and David J Deehan.
    • Institute of Cellular Medicine, University of Newcastle upon Tyne, Newcastle, NE1 7RU, England. drpnbaker@hotmail.com
    • J Bone Joint Surg Am. 2012 Sep 5;94(17):e126.

    BackgroundUnicompartmental knee arthroplasty has been associated with consistently worse implant survival rates than total knee arthroplasty in worldwide arthroplasty registers. The rate of revision and the proportion of revisions performed for unexplained knee pain after either a unicompartmental or total knee arthroplasty were studied to assess if there is evidence to support the hypothesis that the numbers of revisions performed for unexplained knee pain differ between these two implant types.MethodsUsing data from the National Joint Registry (NJR) of England and Wales, we identified 402,714 primary knee arthroplasties (366,965 total knee arthroplasties and 35,749 unicompartmental knee arthroplasties) that were consecutively entered from April 2003 to December 2010. The status of all implants was assessed as of December 2010, at which time 6075 implants (4503 total knee implants and 1572 unicompartmental knee implants) had been revised at a maximum of eight years. Survival analysis and Cox regression analysis with adjustment of differences in age, sex, American Society of Anesthesiologists (ASA) grade, and indication for arthroplasty were performed with use of the end points of revision for any reason, revision for unexplained pain, and revision for other reasons.ResultsRevision for unexplained pain was more common after unicompartmental knee arthroplasty than after total knee arthroplasty (representing 23% of revisions as compared with 9% of revisions; p < 0.001). The five-year rate of revision for unexplained pain was 1.6% for the unicompartmental knee arthroplasty group and 0.2% for the total knee arthroplasty group. With use of Cox regression, the hazard ratio (HR) for unicompartmental knee arthroplasty relative to total knee arthroplasty with the end points of revision for any reason, revision for unexplained pain, and revision for all other reasons were 2.82 (95% confidence interval [CI], 2.66 to 2.99; p < 0.001), 6.76 (95% CI, 5.84 to 7.83; p < 0.001), and 2.39 (95% CI, 2.24 to 2.56; p < 0.001), respectively. The mean time from primary implantation to revision was similar for both implant types.ConclusionsWhile more unicompartmental knee implants than total knee implants were revised for unexplained pain, when these revisions for unexplained pain were discounted, unicompartmental knee arthroplasty still had a significantly greater risk of revision from other reasons than did total knee arthroplasty. The revision rate in isolation may not be a reliable way to compare different implant designs and should instead be considered in the context of the reason for failure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…