• Br J Anaesth · Sep 2010

    Comparative Study

    Effects on coagulation of balanced (130/0.42) and non-balanced (130/0.4) hydroxyethyl starch or gelatin compared with balanced Ringer's solution: an in vitro study using two different viscoelastic coagulation tests ROTEMTM and SONOCLOTTM.

    • M Casutt, A Kristoffy, G Schuepfer, D R Spahn, and C Konrad.
    • Institute of Anesthesiology and Intensive Care, Kantonsspital Lucerne, Lucerne, Switzerland. mattias.casutt@ksl.ch
    • Br J Anaesth. 2010 Sep 1;105(3):273-81.

    BackgroundHydroxyethyl starch (HES) solutions compromise blood coagulation. Low molecular weight, low-substituted HES products, and electrolyte-balanced solutions might reduce this effect. We compared the effects of in vitro haemodilution on blood coagulation with a balanced 6% HES 130/0.42 solution (HES(BAL)), a saline-based 6% HES 130/0.4 solution (HES(SAL)), a balanced lactated Ringer's solution (RL) and a saline-based 4% gelatin solution (GEL).MethodsBlood was obtained from 10 healthy male volunteers and diluted with the test solutions by 33% and 66%. Quality of clot formation was measured using two viscoelastic coagulation tests: SONOCLOT and activated rotation thromboelastometry ROTEM.ResultsOf 16 parameters measured by the viscoelastic devices, we found three statistically significant differences compared with baseline for RL, but 11 for GEL, 10 for HES(SAL), and 11 for HES(BAL) in the 33% haemodilution group (P=0.01). Comparing the different solutions, we observed a significant difference between crystalloids and colloids but none between GEL and HES. In the 66% dilution group, effects on blood coagulation were increased when compared with the 33% dilution group. We found no differences in coagulation impairment between balanced and non-balanced HES products and no differences in the detection of impaired blood coagulation due to haemodilution between the two viscoelastic coagulation tests.ConclusionsBoth ROTEM and SONOCLOT are sensitive tests for the detection of impaired blood coagulation due to haemodilution. There are fewer effects on blood coagulation using crystalloids compared with colloids. The effects of GEL and HES are similar. There is no difference between balanced HES 130/0.42 and non-balanced HES 130/0.4.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.