• Paediatric anaesthesia · Sep 2009

    Laryngeal mask airways--to inflate or to deflate after insertion?

    • Britta S von Ungern-Sternberg, Thomas O Erb, Neil A Chambers, and Mairead Heaney.
    • Department of Anesthesia, Princess Margaret Hospital for Children, and Division of Clinical Sciences, Telethon Institute for Child Health Research, Roberts Road, Subiaco, WA, Australia. Britta.regli-vonungern@health.wa.gov.au
    • Paediatr Anaesth. 2009 Sep 1;19(9):837-43.

    BackgroundHyperinflation of the laryngeal mask airway (LMA) cuff is known to be a risk factor for airway morbidity and increased leakage around the LMA. While the manufacturers' recommendation is to inflate the cuff with the maximum recommended volumes and/or to adjust the cuff pressure to <60 cmH2O, cuff pressures below 40 cmH2O have been shown to be associated with a minimal rate of sore throat and minimal leakage. However, it remains to be determined whether inflation or deflation is needed to achieve favorable pressures. Therefore, we assessed the need for cuff-volume adjustment following insertion of the LMA unchanged straight from the sterile packaging in a prospective audit.MethodsOne thousand children (0-16 years) undergoing elective surgery were consecutively included in this quality of care audit. After taking the LMA from its sterile packaging, the LMA cuff was emptied and the amount of air recorded. Then, the same amount of air was returned into the LMA, the LMA was inserted into the patient, and the cuff pressure was measured using a calibrated cuff manometer.ResultsFollowing insertion of the LMA (without further inflation or deflation of the cuff), 20.5% of children had cuff pressures > or = 60 cmH2, while 55.7% had LMA cuff pressures <40 cmH2O. Cuff pressures were also significantly higher in size 1 LMAs (66.6% had cuff pressures > or = 60 cmH2O and 2% <40 cmH2O) compared with all other sizes (P < 0.05). Furthermore, cuff pressures in LMAs with a poly vinyl chloride (PVC) surface were higher compared to LMAs with a silicone surface (65.2% > or = 60 cmH2O and 9.3% <40 cmH2O vs 9% > or = 60 cmH2O and 67.6% <40 cmH2O, respectively).ConclusionsThis study demonstrates that LMAs, particularly when using small-sized LMAs or LMAs with a more rigid PVC surface, need to be deflated following insertion of the device rather than inflated to avoid cuff hyperinflation. Hence, cuff pressures should be measured routinely using a manometer to minimize potential pressure-related airway complications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.