• Paediatric anaesthesia · Apr 2010

    Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation.

    • Lisen Hockings, Mairead Heaney, Neil A Chambers, Thomas O Erb, and Britta S von Ungern-Sternberg.
    • Department of Anesthesia, Princess Margaret Hospital for Children, Perth, Australia.
    • Paediatr Anaesth. 2010 Apr 1;20(4):313-7.

    BackgroundOptimal inflation of the laryngeal mask airway (LMA) cuff should allow ventilation with low leakage volumes and minimal airway morbidity. Manufacturer's recommendations vary, and clinical end-points have been shown to be associated with cuff hyperinflation and increased leak around the LMA. However, measurement of the intra-cuff pressure of the LMA is not routine in most pediatric institutions, and the optimal intra-cuff pressure in the LMA has not been determined in clinical studies.MethodsThis was a prospective audit in 100 pediatric patients undergoing elective general anesthesia breathing spontaneously via LMA (size 1.5-3). Cuff pressure within the LMA was adjusted using a calibrated pressure gauge to three different values (60, 40, and 20 cmH2O) within the manufacturers' recommended LMA cuff pressure range (< or = 60 cmH2O). Three corresponding inspiratory and expiratory tidal volumes were recorded, and the differences were calculated as the 'leak volume'.ResultsCompared with 20 and 60 cmH2O intra-cuff pressure, measured leakage volumes were the lowest at cuff inflation pressures of 40 cmH2O [median (range) 0.42 (0.09-1.00) ml x kg(-1)] in most patients (83%), while 17% of children demonstrated minimally smaller leakages at 20 cmH2O [0.51 (0.11-1.79) ml x kg(-1)]. Maximum leakage values occurred with cuff pressures of 60 cmH2O in all groups [0.65 (0.18-1.27) ml x kg(-1)] and were not associated with the smallest value of air leakage in any patient.ConclusionUsing cuff manometry, an intra-cuff pressure of 40 cmH2O was associated with reduced leak around the LMA while higher (60 cmH2O) and lower (20 cmH2O) cuff pressures resulted in higher leak volumes during spontaneous ventilation. In spontaneously breathing children, reducing the intra-cuff pressure of pediatric-sized LMAs even below the manufacturers' recommendations allows ventilation with minimized leakage around the LMA cuff.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…