Reg Anesth Pain Med · Jul 2002
Randomized Controlled Trial Clinical TrialEpinephrine is not a useful addition to intrathecal fentanyl or fentanyl-bupivacaine for labor analgesia.
- Stephanie R Goodman, Susan H Kim-Lo, Christopher F Ciliberto, Diane M Ridley, and Richard M Smiley.
- Department of Anesthesiology, Columbia University College of Physicians and Surgeons, New York, New York 10032, USA. srg24@columbia.edu
- Reg Anesth Pain Med. 2002 Jul 1; 27 (4): 374-9.
Background And ObjectivesIntrathecal fentanyl provides effective labor analgesia for a limited time with frequent side effects. We evaluated the effects of adding epinephrine to intrathecal fentanyl with and without bupivacaine.MethodsEighty healthy, term, nulliparous parturients with cervical dilation of 5 cm or less received combined spinal-epidural (CSE) analgesia. Subjects were randomized in a double-blind fashion to 1 of 4 intrathecal solutions containing fentanyl 35 microg with either saline (F); bupivacaine 2.5 mg + saline (FB); bupivacaine 2.5 mg + epinephrine 100 microg (FBE); or epinephrine 100 microg + saline (FE). Patients were evaluated for visual analog pain score, duration of spinal analgesia (time until patient request for additional analgesia), nausea/vomiting, pruritus, sensory and motor block, maternal blood pressure, and fetal heart rate (FHR).ResultsIntrathecal bupivacaine significantly prolonged fentanyl analgesia with or without epinephrine (P =.018), but epinephrine did not significantly prolong the duration of fentanyl alone or with bupivacaine (F, 92 +/- 39 minutes; FB, 125 +/- 31 minutes; FBE, 134 +/- 42 minutes; and FE, 117 +/- 48 minutes). Intrathecal epinephrine was associated with a higher incidence of severe nausea (P =.001), and the FBE group had more lower extremity weakness (P =.047). There was no difference in the incidence of severe pruritus, FHR deceleration, or delivery outcome between the groups.ConclusionsThese results suggest that intrathecal epinephrine does not prolong the duration of fentanyl or fentanyl with bupivacaine for labor analgesia in nulliparous parturients. Additionally, intrathecal epinephrine did not decrease the incidence of side effects and therefore cannot be recommended.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.