• Ann. Thorac. Surg. · Nov 2012

    Clinical Trial

    Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease.

    • Renee N Kreeger, Chandra Ramamoorthy, Susan C Nicolson, Warwick A Ames, Russel Hirsch, Lynn F Peng, Andrew C Glatz, Kevin D Hill, Joan Hoffman, Jon Tomasson, and C Dean Kurth.
    • Departments of Anesthesia and Cardiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio 45229, USA. renee.kreeger@cchmc.org
    • Ann. Thorac. Surg. 2012 Nov 1;94(5):1527-33.

    BackgroundCerebral hypoxia-ischemia remains a complication in children with congenital heart disease. Near-infrared spectroscopy can be utilized at the bedside to detect cerebral hypoxia-ischemia. This study aimed to calibrate and validate an advanced technology near-infrared cerebral oximeter for use in children with congenital heart disease.MethodsAfter institutional review board approval and parental consent, 100 children less than 12 years and less than 40 kg were enrolled. Phase I (calibration) measured arterial and jugular venous saturation (SaO(2), SjO(2)) by co-oximetry simultaneously with device signals to calibrate an algorithm to determine regional cerebral saturation against a weighted average cerebral saturation (0.7 SjO(2) + 0.3 SaO(2)). Phase II (validation) evaluated regional cerebral saturation from the algorithm against the weighted average cerebral saturation by correlation, bias, precision, and A(Root Mean Square) assessed by linear regression and Bland-Altman analysis.ResultsOf 100 patients, 86 were evaluable consisting of 7 neonates, 44 infants, and 35 children of whom 55% were female, 79% Caucasian, and 41% with cyanotic disease. The SaO(2) and regional cerebral saturation ranged from 34% to 100% and 34% to 91%, respectively. There were no significant differences in subject characteristics between phases. For the entire cohort, A(RMS), bias, precision, and correlation coefficient were 5.4%, 0.5%, 5.39%, and 0.88, respectively. Age, skin color, and hematocrit did not affect these values.ConclusionsThis cerebral oximeter accurately measures the absolute value of cerebral saturation in children over a wide range of oxygenation and subject characteristics, offering advantages in assessment of cerebral hypoxia-ischemia in congenital heart disease.Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…