- J Roy, S E McNulty, and M C Torjman.
- Department of Anesthesiology, Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107.
- J Clin Monit. 1991 Jul 1;7(3):249-52.
AbstractWe describe and evaluate a new apparatus that monitors end-tidal carbon dioxide (PETCO2) and augments the inspired oxygen concentration in awake, sedated patients. The unit was evaluated for its effectiveness as an oxygenation device and its accuracy as a predictor of PaCO2 through the correlation of PaCO2 with PETCO2. Twenty cardiac surgical patients, physical status ASA 2-4, participated in this study. The PETCO2 monitoring device consisted of a dual-prong nasal oxygen cannula and a 14-gauge intravenous catheter that was inserted into one limb of the oxygen supply tubing and connected to a Datex gas analyzer (Datex Instrumentation Corp, Helsinki, Finland) to measure PETCO2. The cross-over passage between the prongs was intentionally blocked with the end of a wooden-core cotton swab. The oxygen flow rates were randomly varied (2, 4, and 6 L/min) every 5 minutes, and values for PETCO2 as well as arterial blood samples for analysis of PaCO2 and PaO2 were obtained at the end of each 5-minute period. The accuracy of the system was assessed by comparing the PaCO2-PETCO2 differences (bias) at each oxygen flow rate. The ratios of PETCO2 compared with PaCO2 were 0.98, 0.94, and 0.85, with correlation coefficients of r = 0.81, 0.85, and 0.63, respectively. The PaO2 values were 114, 154, and 183 mm Hg for the corresponding nasal oxygen flow rates of 2, 4, and 6 L/min, respectively. This study indicates that this modified nasal cannula provides supplemental oxygen adequately and yields a satisfactory reflection of the PaCO2 depending on the oxygen flow rate delivered.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.