-
Comparative Study Clinical Trial
Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation.
- W P Bozeman, D Hexter, H K Liang, and G D Kelen.
- Department of Emergency Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Ann Emerg Med. 1996 May 1;27(5):595-9.
Study ObjectivesTo confirm the ability of the esophageal detector device (EDD) to indicate positioning of endotracheal tubes (ETTs) in patients intubated under emergency conditions and to compare the performance of the EDD with that of end-tidal carbon dioxide (ETCO2).MethodsThis single-subject study comprising a prospective case series was conducted in the emergency department of an urban university hospital. All adult patients were intubated either in the ED or by paramedics in the field. ETT position was initially evaluated by means of auscultation, then EDD, and, finally, spectrographic qualitative ETCO2 monitoring in each patient. Discrepancies between the EDD and ETCO2 results were resolved by means of direct laryngoscopy.ResultsIn 100 intubated patients, both the EDD and ETCO2 monitoring detected the single esophageal intubation that occurred. Of the remaining 99 tracheal intubations, the EDD correctly indicated tracheal placement in 98 (sensitivity, 99%) and was indeterminate in 1 case because of blockage of the ETT by secretions resulting from pulmonary edema. By comparison, ETCO2 monitoring correctly indicated tracheal placement in 86 cases (sensitivity, 87%) and was incorrect in 13 cases (P < .01). ETCO2 monitoring failed in 2 patients with pulmonary edema and in 11 patients with cardiac arrest. Among the 37 patients in the cardiac arrest group, the EDD correctly indicated ETT placement in 37 patients (sensitivity, 100%). In contrast, ETCO2 monitoring correctly indicated ETT placement in 26 patients (sensitivity, 70%; P < .01).ConclusionThe EDD reliably confirms tracheal intubation in the emergency patient population. The EDD is more accurate than ETCO2 monitoring in the overall emergency patient population because of its greater accuracy in cardiac arrest patients. [Bozeman WP, Hexter D, Liang HK, Kelen GD: Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.