• Health Technol Assess · Jan 2013

    Randomized Controlled Trial Multicenter Study

    Randomised Assessment of Treatment using Panel Assay of Cardiac markers--Contemporary Biomarker Evaluation (RATPAC CBE).

    • P O Collinson, D C Gaze, P Thokala, and S Goodacre.
    • Clinical Blood Sciences Laboratory, St George's Hospital, London, UK. paul.collinson@stgeorges.nhs.uk
    • Health Technol Assess. 2013 Jan 1;17(15):v-vi, 1-122.

    ObjectivesTo test the diagnostic accuracy for detecting an acute myocardial infarction (AMI) using highly sensitive troponin assays and a range of new cardiac biomarkers of plaque destabilisation, myocardial ischaemia and necrosis; to test the prognostic accuracy for detecting adverse cardiac events using highly sensitive troponin assays and this range of new cardiac biomarkers; and to estimate the cost-effectiveness of using highly sensitive troponin assays or this range of new cardiac biomarkers instead of an admission and 10- to 12-hour troponin measurement.DesignSubstudy of the point-of-care arm of the RATPAC (Randomised Assessment of Treatment using Panel Assay of Cardiac markers) trial.SettingThe emergency departments of six hospitals.ParticipantsProspective admissions with chest pain and a non-diagnostic electrocardiogram randomised to point-of-care assessment or conventional management.InterventionsBlood samples taken on admission and 90 minutes from admission for measurement of cardiac markers [cardiac troponin I (cTnI), myoglobin and creatine kinase MB isoenzyme (CK-MB)] by point-of-care testing. An additional blood sample was taken at admission and 90 minutes from admission for analysis of high-sensitivity cTnI (two methods) and cardiac troponin T (cTnT), myoglobin, heart-type fatty acid-binding protein (H-FABP), copeptin and B-type natriuretic peptide (NTproBNP).Main Outcome Measures1. Diagnostic accuracy compared with the universal definition of myocardial infarction utilising laboratory measurements of cardiac troponin performed at the participating sites together with measurements performed in a core laboratory. 2. Ability of biomarker measurements to predict major adverse cardiac events (death, non-fatal AMI, emergency revascularisation or hospitalisation for myocardial ischaemia) at 3 months' follow-up. 3. Comparison of incremental cost per quality-adjusted life-year (QALY) of different biomarker measurement strategies for the diagnosis of myocardial infarction.ResultsSamples were available from 850 out of 1132 patients enrolled in the study. Measurement of admission myoglobin [area under the curve (AUC) 0.76] and CK-MB (AUC 0.84) was diagnostically inferior and did not add to the diagnostic efficiency of cTnI (AUC 0.90-0.94) or cTnT (AUC 0.92) measurement on admission. Simultaneous measurement of H-FABP and cTnT or cTnI did improve admission diagnostic sensitivity to 0.78-0.92, but only to the same level as that achieved with troponin measured on admission and at 90 minutes from admission (0.78-0.95). Copeptin (AUC 0.62) and NTproBNP (AUC 0.85) measured on admission were not useful as diagnostic markers. As a prognostic marker, troponin measured on admission using a high-sensitivity assay (AUC 0.73-0.83) was equivalent to NTproBNP measurement (AUC 0.77) on admission, but superior to copeptin measurement (AUC 0.58). From modelling, 10-hour troponin measurement is likely to be cost-effective compared with rapid rule-out strategies only if a £30,000 per QALY threshold is used and patients can be discharged as soon as a negative result is available.ConclusionsThe measurement of high-sensitivity cardiac troponin is the best single marker in patients presenting with chest pain. Additional measurements of myoglobin or CK-MB are not clinically effective or cost-effective. The optimal timing for measurement of cardiac troponin remains to be defined. Copeptin measurement is not recommended. H-FABP requires further investigation before it can be recommended for simultaneous measurement with high-sensitivity troponin in patients with acute chest pain.Trial RegistrationISRCTN37823923.FundingThis project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 15. See the HTA programme website for further project information.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.