• J. Cardiothorac. Vasc. Anesth. · Jun 2008

    Comparative Study

    The accuracy of the Vigileo/FloTrac continuous cardiac output monitor.

    • Andreas Zimmermann, Christine Kufner, Stephan Hofbauer, Joachim Steinwendner, Wolfgang Hitzl, Gerhard Fritsch, Roland Schistek, Michael Kirnbauer, and Gernot Pauser.
    • Department of Anaesthesiology and Intensive Care Medicine, Paracelsus Medical University, Salzburg, Austria. a.zimmerman@salk.at
    • J. Cardiothorac. Vasc. Anesth. 2008 Jun 1;22(3):388-93.

    ObjectiveThe Vigileo/FloTrac system (software version 1.01; Edwards Lifesciences, Irvine, CA) determines cardiac output, without calibration, by analysis of the arterial pulse wave. To assess the accuracy of the Vigileo/FloTrac system, it was compared with the pulmonary artery catheter bolus thermodilution method as the current standard method. The study design was prospective and observer blinded.SettingA single university hospital.ParticipantsThirty elective coronary artery bypass graft surgery patients. No special interventions were done to the participants.Measurements And Main ResultsAfter approval by the ethics committee and with written informed consent, synchronized measurements using both methods were made at 7 predefined time points, intraoperatively and postoperatively, producing 192 data pairs for evaluation. The statistical evaluation was performed by using the Bland-Altman method of analysis. In addition, a +/-20% and +/-30% deviation from the pulmonary artery catheter were evaluated (20% criteria and 30% criteria). In total, 46% of measurements did not fulfill the 20% criteria; 26% were outside the 30% limits. The Bland-Altman analysis for all time points showed that 95% of all differences between both methods were within a range between -2.2 and +3.1 L/min. Regression analysis revealed low correlation values at all time points.ConclusionThe described deviation from the standard must be regarded according to the user's needs. Considering the 30% limits of agreement, the Vigileo system (version 1.01) seems sufficiently accurate; applying the 20% criteria, it is not.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…