    Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.

    • Health Devices. 1994 Jun 1;23(6):212-53.

    AbstractIn this issue, we evaluate three liquid disinfecting flexible endoscope reprocessors that can be used with a user-supplied liquid chemical germicide (LCG), primarily for high-level disinfection (HLD). Applying most of the same criteria and test methods, we also evaluated a fourth unit, presented separately, that is marketed as a liquid sterilizing reprocessor and must be used with manufacturer-supplied, single-use containers of LCG. Although the sterilizing unit can be used for rigid endoscopes, surgical instruments, and endoscopic accessories, we evaluated its application to the reprocessing of only flexible endoscopes. Our ratings are based on the following: (1) basic performance, such as compatibility with several different types of endoscopes and LCGs, inclusion of all essential reprocessing phases, and exposure of all endoscope surfaces to the LCG and rinse water; (2) safety, such as ensuring that essential reprocessing phases cannot be skipped or omitted, that personnel exposure to LCG vapors is minimized, and that the reprocessor is unlikely to contaminate the endoscope during reprocessing; and (3) human factors design, such as ease of use and installation. We did not perform microbiological testing to confirm HLD or sterilization by any of the evaluated reprocessors because, with a suitably clean endoscope that is in good condition, no evidence indicates that the LCGs used would not be effective on the surfaces that they contact; also, the results would be unique to the two flexible endoscopes that we used for our testing. We rated all four reprocessors Conditionally Acceptable. The units are Acceptable on the condition that users understand that they cannot be used to process the elevator cable channel of side-viewing duodenoscopes; additional conditions apply only to the liquid disinfecting units. However, if the conditions are met, all four units reduce the likelihood of using a contaminated endoscope on a patient and reduce personnel exposure to the LCG. Selection of a unit will be based on the needs and preferences of the individual healthcare facility. Our ratings also assume that these units will be used according to the manufacturers' instructions and the endoscope's operator's manual. Note that, although the evaluated liquid disinfecting units provide detergent-flushing, post-detergent water-rinse, and post-detergent water-rinse-removal phases, manual cleaning of endoscopes before automatic reprocessing is essential, regardless of which reprocessor is used.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.