Multicenter Study Clinical Trial
Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study.
- Benjamin Gory, Joachim Klisch, Alain Bonafé, Charbel Mounayer, Remy Beaujeux, Jacques Moret, Boris Lubicz, Roberto Riva, and Francis Turjman.
- Department of Interventional Neuroradiology, Hospices Civils de Lyon, Hôpital Neurologique Pierre Wertheimer, 59 Bd Pinel, 69677, Bron, France.
- Neuroradiology. 2013 Nov 1;55(11):1373-8.
IntroductionSolitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. Solitaire Aneurysm Remodeling is the first prospective, consecutive, European multicentric study whose main objective was to evaluate the safety, short-, and long-term efficacy of the Solitaire AB stent. This first analysis is focused on the short-term results.MethodsAfter exclusion of one patient, 66 Solitaire AB stents were used to treat via endovascular approach 64 aneurysms (63 patients) in seven European centers. Technical and clinical complications were recorded. A core laboratory evaluated the angiographic efficacy by using the Raymond classification scale.ResultsThe mean width of aneurysm sac was 7.5 mm, and the mean diameter of aneurysm neck was 4.7 mm. Complete occlusion was achieved in 27 aneurysms (42.2 %); neck remnant was seen in 25 aneurysms (39.1 %) and aneurysm remnant in 12 aneurysms (18.7 %). Technical and clinical complications related to the procedure were encountered in eight patients (12.7 %). Postprocedural modification of the clinical status was observed in one patient (1.6 %). No patients died (0 %); one had a permanent deficit (1.6 %), and one had a transient deficit (1.6 %). Treatment-related mortality was 0 %, and permanent morbidity was 1.6 %.ConclusionThe Solitaire AB stent has an excellent rate of technical success navigation with the absence of dislodgement. The safety and short-term efficacy are comparable to those previously reported with coiling alone. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.