• Vet Anaesth Analg · Nov 2013

    Effects of positive end-expiratory pressure titration on gas exchange, respiratory mechanics and hemodynamics in anesthetized horses.

    • Aline M Ambrósio, Keila K Ida, Maria Tmr Souto, Alexandre H Oshiro, and Denise T Fantoni.
    • Department of Surgery, Faculty of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil.
    • Vet Anaesth Analg. 2013 Nov 1;40(6):564-72.

    ObjectiveTo assess if positive end-expiratory pressure (PEEP) titration improves gas exchange and respiratory mechanics, without hemodynamic impairment in horses during anesthesia.DesignProspective, randomized study.AnimalsThirteen isoflurane-anesthetized healthy horses.MethodsAfter 60 minutes of anesthesia with spontaneous breathing, mechanical ventilation was initiated with an inspiratory-expiratory ratio of 1:2, PEEP of 5 cmH2O, tidal volume of 10-20 mL kg(-1) and respiratory rate adjusted to maintain normocapnia. Constant PEEP of 5 cmH2O was continued (control group; n = 6) or titrated (PEEP group; n = 7) by increasing and decreasing PEEP from 5 to 20 cmH2O at 15-minute intervals. The horses were instrumented with an arterial catheter to measure blood pressure and allow collection of blood for pH and blood gas analysis and a Swan-Ganz catheter for measurement of cardiac output (CO) using thermodilution. Cardiopulmonary assessment was recorded before PEEP titration and after 15 minutes at each PEEP value.ResultsIn the PEEP group, static compliance (range) (Cst 278-463 mL cmH2O(-1)) was significantly higher and the shunt fraction (Q·s/Q·t 7-20%) and the alveolar-arterial oxygen difference [P(A-a)O2 95-325 mmHg] were significantly lower than in the control group [Cst of 246-290 mL cmH2O(-1), Q·s/Q·t of 16-19%, P(A-a)O2 of 253-310 mmHg; p < 0.05]. CO (mean ± SEM) was lower in the PEEP group (23 ± 2 L minute(-1)) at 20 cmH2O PEEP than in the control group (26 ± 4 L minute(-1), p < 0.05), with no significant changes in heart rate, blood pressure or central venous pressure.ConclusionsPEEP titration significantly improved gas exchange and lung compliance, with a small decrease in CO at the highest PEEP level.Clinical RelevanceGas exchange and respiratory mechanics impairment during inhalation anesthesia can be treated using PEEP titration from 5 to 20 cmH2O, without clinically important hemodynamic effects in healthy horses.© 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…