-
Randomized Controlled Trial
ED(50) and ED(95) of intrathecal bupivacaine in morbidly obese patients undergoing cesarean delivery.
- Brendan Carvalho, Jeremy Collins, David R Drover, Lindsey Atkinson Ralls, and Edward T Riley.
- Department of Anesthesia, Stanford University School of Medicine, Stanford, California 94305, USA. bcarvalho@stanford.edu
- Anesthesiology. 2011 Mar 1;114(3):529-35.
BackgroundIt has been suggested that morbidly obese parturients may require less local anesthetic for spinal anesthesia. The aim of this study was to determine the effective dose (ED(50)/ED(95)) of intrathecal bupivacaine for cesarean delivery in morbidly obese patients.MethodsMorbidly obese parturients (body mass index equal to or more than 40) undergoing elective cesarean delivery were enrolled in this double-blinded study. Forty-two patients were randomly assigned to receive intrathecal hyperbaric bupivacaine in doses of 5, 6, 7, 8, 9, 10, or 11 mg (n = 6 per group) coadministered with 200 μg morphine and 10 μg fentanyl. Success (induction) was defined as block height to pinprick equal to or more than T6 and success (operation) as success (induction) plus no requirement for epidural supplementation throughout surgery. The ED(50)/ED(95) values were determined using a logistic regression model.ResultsED(50) and ED(95) (with 95% confidence intervals) for success (operation) were 9.8 (8.6-11.0) and 15.0 (10.0-20.0), respectively, and were similar to corresponding values of a nonobese population determined previously using similar methodology. We were unable to measure ED(50)/ED(95) values for success (induction) because so few blocks failed initially, even at the low-dose range. There were no differences with regard to secondary outcomes (i.e., hypotension, vasopressor use, nausea, and vomiting).ConclusionsObese and nonobese patients undergoing cesarean delivery do not appear to respond differently to modest doses of intrathecal bupivacaine. This dose-response study suggests that doses of intrathecal bupivacaine less than 10 mg may not adequately ensure successful intraoperative anesthesia. Even when the initial block obtained with a low dose is satisfactory, it will not guarantee adequate anesthesia throughout surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.