Reg Anesth Pain Med · Sep 2009
Randomized Controlled Trial Comparative StudyElectrical stimulation versus ultrasound guidance for popliteal-sciatic perineural catheter insertion: a randomized controlled trial.
- Edward R Mariano, Gloria S Cheng, Lynna P Choy, Vanessa J Loland, Richard H Bellars, Navparkash S Sandhu, Michael L Bishop, Daniel K Lee, Rosalita C Maldonado, and Brian M Ilfeld.
- Department of Anesthesiology, University of California, San Diego Medical Center, San Diego, CA, USA.
- Reg Anesth Pain Med. 2009 Sep 1;34(5):480-5.
BackgroundSciatic perineural catheters via a popliteal fossa approach and subsequent local anesthetic infusion provide potent analgesia and other benefits after foot and ankle surgery. Electrical stimulation (ES) and, more recently, ultrasound (US)-guided placement techniques have been described. However, because these techniques have not been compared in a randomized fashion, the optimal method remains undetermined. Therefore, we tested the hypotheses that popliteal-sciatic perineural catheters placed via US guidance require less time for placement and produce equivalent results, as compared with catheters placed using ES.MethodsPreoperatively, subjects receiving a popliteal-sciatic perineural catheter for foot and/or ankle surgery were randomly assigned to either the ES with a stimulating catheter or US-guided technique with a nonstimulating catheter. The primary end point was catheter insertion duration (in minutes) starting when the US transducer (US group) or catheter-placement needle (ES group) first touched the patient and ending when the catheter-placement needle was removed after catheter insertion.ResultsAll US-guided catheters were placed per protocol (n = 20), whereas only 80% of stimulation-guided catheters could be placed per protocol (n = 20, P = 0.106). All catheters placed per protocol in both groups resulted in a successful surgical block. Perineural catheters placed by US took a median (10th-90th percentile) of 5.0 min (3.9-11.1 min) compared with 10.0 min (2.0-15.0 min) for stimulation (P = 0.034). Subjects in the US group experienced less pain during catheter placement, scoring discomfort a median of 0 (0.0-2.1) compared with 2.0 (0.0-5.0) for the stimulation group (P = 0.005) on a numeric rating scale of 0 to 10.ConclusionsPlacement of popliteal-sciatic perineural catheters takes less time and produces less procedure-related discomfort when using US guidance compared with ES.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.