• J. Cardiovasc. Electrophysiol. · Nov 2012

    Randomized Controlled Trial

    Implantation feasibility, procedure-related adverse events and lead performance during 1-year follow-up in patients undergoing triple-site cardiac resynchronization therapy: a substudy of TRUST CRT randomized trial.

    • Radosław Lenarczyk, Oskar Kowalski, Beata Sredniawa, Patrycja Pruszkowska-Skrzep, Michał Mazurek, Ewa Jędrzejczyk-Patej, Aleksandra Woźniak, Sławomir Pluta, Jan Głowacki, and Zbigniew Kalarus.
    • Department of Cardiology, Congenital Heart Disease and Electrotherapy, Silesian Medical University, Silesian Center for Heart Disease, Zabrze, Poland. elfizab@poczta.onet.pl
    • J. Cardiovasc. Electrophysiol. 2012 Nov 1;23(11):1228-36.

    IntroductionThis substudy was to assess implantation feasibility and long-term safety of triple-site resynchronization therapy (CRT) in a series of consecutive patients included in a randomized trial.Methods And ResultsOne hundred consecutive patients enrolled into Triple-Site Versus Standard Cardiac Resynchronization Therapy Randomized Trial were analyzed. Eligibility criteria included NYHA class III-IV, sinus rhythm, QRS ≥ 120 milliseconds, left ventricular ejection fraction ≤35%, and significant mechanical dyssynchrony. Patients were randomized in a 1:1 ratio to conventional or triple-site CRT with defibrillator-cardioverter. After 12 months of resynchronization 30% of patients with conventional resynchronization and 12.5% with triple-site CRT were in NYHA functional class III or IV (P < 0.05). Implantation of triple-site systems was significantly longer (median 125 minutes vs 96 minutes; P < 0.001), with higher fluoroscopic exposure, especially in patients with very enlarged left ventricle or pulmonary hypertension. Implantation success-rate was similar in the triple-site and conventional group (94% vs 98%; P = NS); however, additional techniques had to be used in a greater proportion of the triple-site patients (33.3% vs 16%; P < 0.05). Long-term lead performance tests revealed significantly higher pacing threshold and lower impedance in the triple-site group. The 1-year incidence of serious, CRT-related adverse events was similar in triple-site and conventional group (20.8% vs 30%; P = NS).ConclusionsTriple-site CRT is associated with more pronounced functional improvement than standard resynchronization. This form of pacing is equally safe and feasible as the conventional CRT. However, triple-site procedure is more time-consuming, associated with higher radiation exposure and the need to use additional techniques. Triple-site resynchronization is associated with less favorable electrical lead characteristics.© 2012 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.