Am. J. Obstet. Gynecol. · Sep 1997
Multicenter Study Comparative StudyMulticenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry.
- B Carbonne, B Langer, F Goffinet, F Audibert, D Tardif, F Le Goueff, M Laville, and F Maillard.
- Maternité Port Royal-Baudelocque, Services de Gynécologie-Obstétrique, Paris, France.
- Am. J. Obstet. Gynecol. 1997 Sep 1;177(3):593-8.
ObjectiveOur purpose was to compare the predictive value of intrapartum fetal pulse oximetry with that of fetal blood analysis for an abnormal neonatal outcome in case of an abnormal fetal heart rate.Study DesignA prospective multicenter observational study was conducted from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded with a Nellcor N-400 fetal pulse oximeter in case of an abnormal fetal heart rate during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis obtained before birth (i.e., either at full dilatation or before cesarean section when indicated) were compared with the neonatal status. The criteria for an abnormal neonatal outcome were (1) an umbilical arterial blood pH < or = 7.15 and (2) a combined variable including 5-minute Apgar score < or = 7, umbilical arterial pH < or = 7.15, secondary respiratory distress, transfer in a neonatal care unit, or neonatal death.ResultsAt a 7.20 threshold for fetal scalp pH and 30% for fetal oxygen saturation (i.e., the 10th percentile in the study population), the predictive value of fetal pulse oximetry was similar to that of fetal blood analysis for an arterial umbilical pH < or = 7.15 and for an abnormal neonatal outcome (positive predictive value 56% vs 55%, negative predictive value 81% vs 82%, sensitivity 29% vs 35%, and specificity 93% vs 91%, respectively). The receiver-operator characteristic curve showed similar performance of either technique for cutoff values < or = 7.20 for fetal blood pH and < or = 30% for fetal oxygen saturation, whereas fetal pulse oximetry became superior at higher thresholds.ConclusionThe predictive value of intrapartum fetal pulse oximetry can be favorably compared with that of fetal blood analysis. Randomized controlled management trials can now be performed to assess potential clinical benefits of this new tool.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.