Scand J Trauma Resus · Oct 2015
Observational StudyMonitoring of in-hospital cardiac arrest events with the focus on Automated External Defibrillators - a retrospective observational study.
- Thomas Wurmb, Tina Vollmer, Peter Sefrin, Martin Kraus, Oliver Happel, Christian Wunder, Andreas Steinisch, Norbert Roewer, and Sebastian Maier.
- Department of Anaesthesiology, University Hospital of Wuerzburg, Oberduerrbacherstrasse 6, 97080, Wuerzburg, Germany. wurmb_t@ukw.de.
- Scand J Trauma Resus. 2015 Jan 1; 23: 87.
BackgroundPatients with cardiac arrest have lower survival rates, when resuscitation performance is low. In In-hospital settings the first responders on scene are usually nursing staff without rhythm analysing skills. In such cases Automated External Defibrillators (AED) might help guiding resuscitation performance. At the Wuerzburg University Hospital (Germany) an AED-program was initiated in 2007. Aim of the presented study was to monitor the impact of Automated External Defibrillators on the management of in-hospital cardiac arrest events.MethodsThe data acquisition was part of a continuous quality improvement process of the Wuerzburg University Hospital. For analysing the CPR performance, the chest compression rate (CCR), compression depth (CCD), the no flow fraction (NFF), time interval from AED-activation to the first compression (TtC), the time interval from AED-activation to the first shock (TtS) and the post schock pause (TtCS) were determined by AED captured data. A questionnaire was completed by the first responders.ResultsFrom 2010 to 2012 there were 359 emergency calls. From these 53 were cardiac arrests with an AED-application. Complete data were available in 46 cases. The TtC was 34 (32-52) seconds (median and IQR).The TtS was 30 (28-32) seconds (median and IQR). The TtCS was 4 (3-6) seconds (median and IQR). The CCD was 5.5 ± 1 cm while the CCR was 107 ± 11/min. The NFF was calculated as 41 %. ROSC was achieved in 21 patients (45 %), 8 patients (17 %) died on scene and 17 patients (37 %) were transferred under ongoing CPR to an Intensive Care Unit (ICU).ConclusionThe TtS and TtC indicate that there is an AED-user dependent time loss. These time intervals can be markedly reduced, when the user is trained to interrupt the AED's "chain of advices" by placing the electrode-paddles immediately on the patient's thorax. At this time the AED switches directly to the analysing mode. Intensive training and adaption of the training contents is needed to optimize the handling of the AED in order to maximize its advantages and to minimize its disadvantages.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.