-
Neurological research · Apr 2009
Clinical TrialInitial experience with silver-impregnated polyurethane ventricular catheter for shunting of cerebrospinal fluid in patients with infected hydrocephalus.
- Yusuf Izci, Halilibrahim Secer, Cemal Akay, and Engin Gonul.
- Department of Neurosurgery, Gulhane Military Medical Academy, Ankara, Turkey. yusufizci@yahoo.com
- Neurol. Res. 2009 Apr 1;31(3):234-7.
ObjectiveInfection is a major complication and risk factor of cerebrospinal fluid (CSF) shunting procedures. Recently, antibiotic-impregnated shunt systems have been developed in an attempt to prevent or reduce the CSF infection. The aim of this study was to determine the efficacy of silver-impregnated polyurethane ventricular catheter for shunting of CSF in patients with infected hydrocephalus.MethodsSeven patients who had hydrocephalus with high protein level and positive CSF culture underwent implantation of ventriculoperitoneal shunt with silver-impregnated polyurethane ventricular catheter. All of them experienced shunt failure previously due to infection. The Silverline ventricular catheter, which was connected to the Miethke gravity-assisted valve system and peritoneal catheter, was used in all patients. The mean follow-up period after operation was 14 months. Cerebrospinal fluid samples from the reservoir of the shunts were obtained at the end of the third month after operation in all patients.ResultsThe CSF protein level of the patients was reduced significantly, and the CSF culture became negative after shunt placement with silver-impregnated polyurethane ventricular catheters. The mean CSF silver (Ag) level was 0.51 ng/ml [parts per billion (ppb)], and blood Ag level was 3.65 ng/ml (ppb) at the first month after operation. No shunt obstruction or infection was observed in the follow-up period.ConclusionSilver-impregnated polyurethane ventricular catheters appear to be safe and well tolerated in patients who sustained infected hydrocephalus. Preliminary results suggest a complete improvement of infection. Longer follow-up and large number of patients are needed to more accurately assess the efficacy of these catheters.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.