• J Trauma · Oct 2003

    Comparative Study

    The esophageal Doppler monitor in mechanically ventilated surgical patients: does it work?

    • Hani M Seoudi, Melissa F Perkal, Ann Hanrahan, and Peter B Angood.
    • Department of Surgery, Section of Trauma and Surgical Critical Care, Yale University School of Medicine, New Haven, Connecticut, USA.
    • J Trauma. 2003 Oct 1;55(4):720-5; discussion 725-6.

    BackgroundAssessment of cardiac volumes and cardiac output (CO) using a pulmonary artery catheter (PAC) in mechanically ventilated patients can be inconsistent and difficult. The esophageal Doppler monitor (EDM) is emerging as a potential alternative to the PAC. This prospective study evaluated the comparative accuracy between the PAC and EDM for preload assessment and CO in mechanically ventilated surgical patients. METHODS The EDM was placed in 15 patients with PACs in place. A total of 187 simultaneously measured EDM and PAC comparative data sets were obtained. The Pearson correlation (r) was used to compare measurements, with significance defined as a value of p < 0.05.ResultsCO measured by EDM and PAC correlated closely (r = 0.97, p < 0.0001). Corrected flow time (FTc), a measure of left ventricular filling, correlated with PAC CO to the same degree as pulmonary capillary wedge pressure (PCWP) when positive end-expiratory pressure (PEEP) was < 10 cm H2O (FTc, r = 0.51; PCWP, r = 0.56). When PEEP was > or = 10 cm H2O, FTc correlated with PAC CO better than PCWP (FTc, r = 0.85; PCWP, r = 0.29).ConclusionFTc correlates with EDM and PAC CO better than PCWP. On the basis of the current study, it is reasonable to conclude that the EDM is a valuable adjunct technology for CO and preload assessment in surgical patients on mechanical ventilation, regardless of the level of mechanical ventilatory support.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…