    A simplified method for separate measurements of lung and chest wall mechanics in ventilator-treated patients.

    • S Kárason, K L Karlsen, S Lundin, and O Stenqvist.
    • Department of Anesthesia & Intensive Care, Sahlgrenska University Hospital, Göteborg, Sweden.
    • Acta Anaesthesiol Scand. 1999 Mar 1;43(3):308-15.

    BackgroundAirway pressure measurements above the endotracheal tube will be distorted because of endotracheal tube resistance. To separate lung and chest wall compliance, esophageal pressure is conventionally measured with an air-filled balloon catheter, which is difficult to insert in unconscious patients. We have developed a methodology with fluid-filled catheters for intratracheal and esophageal pressure measurements.MethodsTwelve anesthetized patients were studied. Tidal volumes were measured by side-stream spirometry. Airway pressures were measured at the Y-piece and in the trachea with fluid-filled pressure lines. Esophageal pressure was measured via the narrow lumen in a fluid-filled Salem double-lumen stomach tube, which was slowly retracted from the stomach up through the esophagus until maximal respiratory pressure readings and minimal cardiac artifacts were obtained. Lung mechanics were measured at different tidal volumes (TV) and positive end-expiratory pressure (PEEP).ResultsThere was a significant difference between airway pressures at the Y-piece and in the trachea. Total compliance significantly increased with increasing TV and decreased with increasing PEEP. Chest wall compliance increased significantly with increasing TV, while lung compliance did not change significantly. Two patients showed repeatedly marked increase in lung compliance at one specific ventilatory setting, an increase the proportion of which was not reflected by changes in total compliance.ConclusionsY-piece pressures are not representative of intratracheal pressures, which can be measured by inserting a fluid-filled pressure line through the tube. Esophageal pressure is easily recorded with a fluid-filled Salem double-lumen catheter. Large changes in lung compliance may pass unnoticed when only total compliance is monitored. Monitoring of lung compliance may offer an improved basis for decisions about ventilator settings.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.