Comparison of volume control and pressure control ventilation: is flow waveform the difference?
- K Davis, R D Branson, R S Campbell, and D T Porembka.
- Department of Surgery, University of Cincinnati Medical Center, OH 45267-0558, USA.
- J Trauma. 1996 Nov 1;41(5):808-14.
ObjectiveTo examine the hypothesis that a decelerating inspiratory flow waveform is responsible for improvements in gas exchange during pressure control ventilation for acute lung injury.DesignProspective, controlled, crossover study.Measurements And Main ResultsTwenty-five patients with acute lung injury requiring mechanical ventilation with a positive-end expiratory pressure > or = 10 cm H2O, ventilator frequency of > or = 8 bpm, inspired oxygen concentration of > or = 0.50, peak inspiratory pressure > or = 40 cm H2O, and requiring sedation and paralysis were studied. Patients were ventilated at a tidal volume of 10 mliters/kg, respiratory frequency was set to maintain a pH > 7.30 and PaCO2 < 50 mm Hg, and positive end-expiratory pressure (PEEP) set to maintain Pao2 > 70 mm Hg or Sao2 > 93% with an Fio2 < or = 0.50. In random sequence, ventilator mode was changed from volume control with a square flow waveform, pressure control ventilation with a decelerating flow waveform, or volume control ventilation with a decelerating flow waveform. Tidal volume, minute ventilation, and airway pressures were continuously measured at the proximal airway. After 2 hours of ventilation in each mode, arterial and mixed venous blood gases were drawn and cardiac output determined by thermodilution. Dead space to tidal volume ratio was determined from mixed expired gas concentrations and Paco2. During volume control ventilation with a square flow waveform, Pao2 was decreased (75 +/- 11 mm Hg vs. 85 +/- 9 mm Hg and 89 +/- 12 mm Hg), p < 0.05, and peak inspiratory pressure was increased (50 +/- 9 cm H2O vs. 42 +/- 7 cm H2O and 39 +/- 9 cm H2O) p < 0.05 compared to volume control with a decelerating flow waveform and pressure control ventilation. Mean airway pressure was also lower with volume control with a square flow waveform (17 +/- 4 cm H2O vs. 20 +/- 4 cm H2O and 21 +/- 3 cm H2O) compared to volume control with a decelerating flow waveform and pressure control ventilation. There were no differences in hemodynamic parameters.ConclusionsBoth pressure control ventilation and volume control ventilation with a decelerating flow waveform provided better oxygenation at a lower peak inspiratory pressure and higher mean airway pressure compared to volume control ventilation with a square flow waveform. The results of our study suggest that the reported advantages of pressure control ventilation over volume control ventilation with a square flow waveform can be accomplished with volume control ventilation with a decelerating flow waveform.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.