• Cochrane Db Syst Rev · Sep 2015

    Review Meta Analysis

    Dressings and securement devices for central venous catheters (CVC).

    • Amanda J Ullman, Marie L Cooke, Marion Mitchell, Frances Lin, Karen New, Debbie A Long, Gabor Mihala, and Claire M Rickard.
    • NHMRC Centre of Research Excellence in Nursing, Centre for Health Practice Innovation, Menzies Health Institute Queensland, Griffith University, 170 Kessels Road, Brisbane, Queensland, Australia, 4111.
    • Cochrane Db Syst Rev. 2015 Sep 10 (9): CD010367.

    BackgroundCentral venous catheters (CVCs) play a vital role in the management of acute and chronic illness. Dressings and securement devices must ensure CVCs do not dislodge or fall out, provide a barrier protection from microbial colonisation and infection, and be comfortable for the patient. There is a large range of dressing and securement products available for clinicians to use.ObjectivesTo compare the available dressing and securement devices for CVCs, in terms of catheter-related bloodstream infection (BSI), catheter colonisation, entry- and exit-site infection, skin colonisation, skin irritation, failed catheter securement, dressing condition and mortality.Search MethodsIn June 2015 we searched: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL); The Database of Abstracts of Reviews of Effects (DARE); NHS Economic Evaluation Database (NHSEED); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; EBSCO CINAHL; six clinical trial registries and reference lists of identified trials. There were no restrictions based on language or date of publication or study setting.Selection CriteriaWe included randomised controlled trials that evaluated the effects of dressing and securement devices for CVCs. All types of CVCs were included, i.e. short- and long-term CVCs, tunnelled and non-tunnelled, port-a-caths, haemodialysis catheters, and peripherally-inserted central catheters (PICCs).Data Collection And AnalysisWe used standard Cochrane Collaboration methods including independent review of titles and abstracts for relevance, data extraction, and risk of bias assessment of the included studies by two review authors. Results are expressed using risk ratio (RR) for categorical data with 95% confidence intervals (CIs). For outcomes best presented as a rate-per-time-period, rate ratios and standard errors have been used. We performed multiple treatment meta-analyses to rank the effectiveness of each intervention for each outcome.Main ResultsWe included 22 studies involving 7436 participants comparing nine different types of securement device or dressing. All included studies were at unclear or high risk of performance bias due to the different appearances of the dressings and securement devices. The extent of blinding of outcome assessment was unclear in most studies. The quality of evidence varied between different comparisons and outcomes. We mainly downgraded the quality of evidence for imprecision, indirectness, risk of bias and inconsistency.It is unclear whether there is a difference in the rate of catheter-related BSI between securement with gauze and tape and standard polyurethane (SPU) (RR 0.64, 95% CI 0.26 to 1.63, low quality evidence), or between chlorhexidine gluconate-impregnated (CGI) dressings and SPU (RR 0.65, 95% CI 0.40 to 1.05, moderate quality evidence). There is high quality evidence that medication-impregnated dressings reduce the incidence of catheter-related BSI relative to all other dressing types (RR 0.60, 95% CI 0.39 to 0.93).There is moderate quality evidence that CGI dressings reduce the frequency of catheter-related BSI per 1000 patient days compared with SPU dressings (RR 0.51, 95% CI 0.33 to 0.78).There is moderate quality evidence that catheter tip colonisation is reduced with CGI dressings compared with SPU dressings (RR 0.58, 95% CI 0.47 to 0.73), but the relative effects of gauze and tape and SPU are unclear (RR 0.95, 95% CI 0.51 to 1.77, very low quality evidence). It is unclear if there is a difference in rates of skin irritation or damage when CGI dressings are compared with SPU dressings (moderate quality evidence) (RR 11.17, 95% CI 0.84 to 149.48).A multiple treatment meta-analysis found sutureless securement devices as likely to be the most effective at reducing the incidence of catheter-related BSI (low quality evidence), with CGI dressings ranked second (low quality evidence).Authors' ConclusionsMedication-impregnated dressing products reduce the incidence of catheter-related BSI relative to all other dressing types. There is some evidence that CGI dressings, relative to SPU dressings, reduce catheter-related BSI for the outcomes of frequency of infection per 1000 patient days, risk of catheter tip colonisation and possibly risk of catheter-related BSI. A multiple treatment meta-analysis found that sutureless securement devices are likely to be the most effective at reducing catheter-related BSI though this is low quality evidence. Most studies were conducted in intensive care unit (ICU) settings. More, high quality research is needed regarding the relative effects of dressing and securement products for CVCs. Future research may adjust the estimates of effect for the products included in this review and is needed to assess the effectiveness of new products.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.