• J Orthop Trauma · May 1998

    Randomized Controlled Trial Comparative Study Clinical Trial

    Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw.

    • J E Madsen, L Naess, A K Aune, A Alho, A Ekeland, and K Strømsøe.
    • Department of Orthopaedics, Ullevål Hospital, University of Oslo, Norway.
    • J Orthop Trauma. 1998 May 1;12(4):241-8.

    ObjectiveTo compare the results after operative treatment of unstable per- and subtrochanteric fractures with the Gamma nail, compression hip screw (CHS), or dynamic hip screw with a laterally mounted trochanteric stabilizing plate (DHS/TSP).DesignProspective.PatientsOne hundred seventy patients with unstable trochanteric femoral fractures surviving six months after operation. Eighty-five patients were randomized to treatment with the Gamma nail (n = 50, Gamma group) or the compression hip screw (n = 35, CHS group) and compared with a consecutive series of eighty-five patients operated with the dynamic hip screw with a laterally mounted trochanteric stabilizing plate (DHS/TSP group)Main Outcome MeasurementsRadiographs were analyzed for fracture classification, evaluation of fracture reduction, implant positioning, later fracture dislocation, and other complications. Pre- and postoperative functional status of the patients were recorded, with a minimum of six months follow-up.ResultsEighteen percent of the patients in the Gamma group, 34 percent in the CHS group, and 9 percent in the DHS/TSP group suffered significant secondary fracture dislocation during the six months follow-up, leading to a varus malunion, lag screw cutout, or excessive lag screw sliding with medialization of the distal fracture fragment. Two patients (4.0 percent) in the Gamma group suffered an implant-related femoral fracture below the nail, and one had a deep infection. The reoperation rates were 8.0 percent in the Gamma group, 2.9 percent in the CHS group, and 5.9 percent in the DHS/TSP group. All but one fracture in the Gamma and CHS groups and two fractures in the DHS/TSP group healed within six months. Approximately three-fourths of the patients had returned to their preoperative walking ability after six months, with a trend toward better functional outcome in the DHS/TSP group. Use of a TSP reduced the secondary lag screw sliding as compared with the conventional CHS, without affecting fracture healing.ConclusionThe TSP may be an aid in the treatment of these difficult fractures because the problem with femoral shaft fractures using the Gamma nail is avoided and the medialization of the distal fracture fragment frequently associated with the CHS is prevented.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.