• J. Thorac. Cardiovasc. Surg. · Nov 2010

    Multicenter Study

    Influence of the On-X mechanical prosthesis on intermediate-term major thromboembolism and hemorrhage: a prospective multicenter study.

    • Vincent Chan, W R Eric Jamieson, B-Khanh Lam, Marc Ruel, Hilton Ling, Guy Fradet, and Thierry G Mesana.
    • Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
    • J. Thorac. Cardiovasc. Surg. 2010 Nov 1;140(5):1053-8.e2.

    ObjectivesLong-term thromboembolic and hemorrhagic outcomes after mechanical valve replacement have been well described; however, few studies have described these outcomes after valve replacement with the On-X mechanical prosthesis (On-X Life Technologies, Inc, Austin, Tex).MethodsBetween 2003 and 2008, 737 patients underwent either aortic valve replacement (n = 400), mitral valve replacement (n = 282), or double-valve replacement (n = 55). Longitudinal performance, freedom evaluation, and risk analysis were assessed with regard to major thromboembolism and hemorrhage. Risk modeling was performed with 16 variables inclusive of age, atrial fibrillation, concomitant coronary artery bypass grafting, New York Heart Association class, and ventricular dysfunction.ResultsEarly mortality was 2.5% (n = 10) for aortic valve replacement and 3.2% (n = 9) for mitral valve replacement. Late mortality for aortic valve replacement was 4.8% per patient-year and 6.0% per patient-year for mitral valve replacement. Five-year freedom from major thromboembolism was 96.5% ± 1.2% for aortic valve replacement and 97.7% ± 0.9% for mitral valve replacement. Five-year freedom from hemorrhage was 93.6% ± 1.8% for aortic valve replacement and 95.7% ± 1.5% for mitral valve replacement. Concomitant coronary artery bypass grafting was predictive of major thromboembolism after aortic valve replacement (hazard ratio, 5.3; P = .02) and antithrombotic hemorrhage after mitral valve replacement (hazard ratio, 4.7; P = .03). No other independent predictors of major thromboembolism or hemorrhage were identified. One thrombosed mitral prosthesis was observed after deliberate discontinuation of anticoagulation. The major thromboembolic events occurred with variation of international normalized ratio levels inclusive of subtherapeutic levels. The majority of hemorrhagic events occurred with high international normalized ratio levels.ConclusionsThe On-X mechanical prosthesis provides favorable intermediate-term results with regard to major thromboembolism and hemorrhage.Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…