Randomized Controlled Trial Comparative Study Clinical Trial
Active compression-decompression. A new method of cardiopulmonary resuscitation. Cardiopulmonary Resuscitation Working Group.
- T J Cohen, K J Tucker, K G Lurie, R F Redberg, J P Dutton, K A Dwyer, T M Schwab, M C Chin, A M Gelb, and M M Scheinman.
- Department of Medicine, University of California, San Francisco.
- JAMA. 1992 Jun 3;267(21):2916-23.
ObjectiveTo describe and compare with standard cardiopulmonary resuscitation (CPR) in humans a new form of CPR that involves both active compression and active decompression of the chest.DesignPatients in cardiac arrest in whom standard advanced cardiac life support failed were randomized to receive 2 minutes of either standard or active compression-decompression (ACD) CPR using a custom, hand-held suction device, followed by 2 minutes of the alternate technique. The ACD device was applied midsternum and used to perform CPR according to the guidelines of the American Heart Association: 80 compressions per minute, compression depth of 3.8 to 5 cm, 50% duty cycle, and constant-volume ventilation. Mechanical Thumper CPR was also compared in five patients. End-tidal carbon dioxide (ETCO2) concentrations and hemodynamic variables were measured. Transesophageal Doppler echocardiography was used to assess contractility, the velocity time integral (an analogue of cardiac output), and diastolic myocardial filling times.ResultsTen patients were enrolled. The mean +/- SD ETCO2 was 4.3 +/- 3.8 mm Hg with standard CPR and 9.0 +/- 3.9 mm Hg with ACD CPR (P less than .0001). Systolic arterial pressure with standard CPR was 52.5 +/- 14.0 mm Hg and with ACD CPR, 88.9 +/- 24.7 mm Hg (P less than .003). The velocity time integral increased from 7.3 +/- 2.6 cm with standard CPR to 17.5 +/- 5.6 cm with ACD CPR (P less than .0001), and diastolic filling times increased from 0.23 +/- .09 seconds with standard CPR to 0.37 +/- .12 seconds with ACD CPR (P less than .004). Mechanical Thumper CPR consistently underperformed both standard and ACD CPR. Minute ventilation obtained in four patients during ACD CPR without endotracheal ventilation was 6.6 +/- 0.9 L/min. After 1 hour of standard CPR failed, three of 10 patients randomized to ACD CPR rapidly converted to a hemodynamically stable rhythm following 2 minutes of ACD CPR.ConclusionACD CPR is a simple manual technique that improved cardiopulmonary circulation in 10 patients during cardiac arrest. Although ACD CPR may have produced a return of spontaneous circulation in three patients refractory to standard measures, its impact on survival when used early in cardiac arrest remains to be determined.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.