Reg Anesth Pain Med · Mar 2010
Ultrasonographic appearance of intraneural injections in the porcine model.
- Fernando R Altermatt, Thomas J Cummings, Kathryn M Auten, Mathew F Baldwin, Samuel W Belknap, and James D Reynolds.
- Departments of Anesthesiology and Pathology and Division of Ambulatory Anesthesiology, Duke University Medical Center, Durham, NC 27710, USA. fernando.altermatt@gmail.com
- Reg Anesth Pain Med. 2010 Mar 1;35(2):203-6.
BackgroundUltrasonographic (US) images of apparent intraneural injection of local anesthetic solutions have been reported. We aimed to define US signs of intraneural (ie, subepineural) injection using a histologic standard in an animal model and compare these signs with other potential markers of intraneural injection, including low nerve stimulation current thresholds and high injection pressures.MethodsIn 6 anesthetized adult swine, bilateral brachial plexus and femoral nerves were contacted by needles and penetrated. India ink was injected intraneurally under US monitoring. The minimum current that elicited a motor response was recorded. Injection pressures were measured using a digital manometer. Nerves were then excised, processed, and subjected to histologic analysis.ResultsNerve expansion during injection was visualized under ultrasonography in all procedures. Electrical current intensity to elicit motor response to nerve stimulation varied between 0.2 and 3.3 mA with the needle tip positioned intraneurally. The mean injection pressure was 7.40 +/- 8.07 psi (range, 0.07-31.5 psi), with 80% of injections between 0.61 and 15.0 psi. None of 24 intraneural injections resulted in histologic evidence of intrafascicular injection (95% confidence interval, 0.0%-16.3%).ConclusionsUltrasonographic images compatible with nerve swelling during an injection are consistent with true intraneural injections as demonstrated by histologic analysis. Under the conditions studied, intensity of the stimulating current required to elicit motor response was not associated with intraneural needle placement. In the absence of fascicular injury, intraneural injections were associated with low injection pressure, although false-positive results can occur.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.