-
Anesthesia and analgesia · Dec 2009
Comparative StudyA comparison of transmittance and reflectance pulse oximetry during vascular surgery.
- David B Wax, Philip Rubin, and Steven Neustein.
- Department of Anesthesiology, Mount Sinai School of Medicine, 1 Gustave L. Levy Place, Box 1010, New York, NY 10029, USA. david.wax@mssm.edu
- Anesth. Analg. 2009 Dec 1;109(6):1847-9.
BackgroundNew reflectance pulse oximetry probes placed on the forehead may be an improvement over transmittance probes placed on a finger, toe, or earlobe in patients with compromised perfusion. We compared the reliability and accuracy of the 2 types of probes in patients undergoing vascular surgery.MethodsPatients with peripheral vascular disease undergoing vascular surgery under general anesthesia were monitored with both a transmittance earlobe probe and a reflectance forehead probe. Spo(2) was recorded continuously from both probes, and arterial blood gas samples were analyzed when clinically indicated. The average values from both probes over each minute were compared using Bland-Altman analysis.ResultsTwenty patients were included yielding a total of 3993 1-min averaged data pairs. Neither probe failed to report a value for more than 1 min. A Bland-Altman plot showed the limits of agreement between the probes of -4.0% to +2.6%. Twenty-eight arterial blood samples were analyzed for 14 patients and Sao(2) closely matched both Spo(2) probe values at the time of sampling. Compared with Sao(2), analysis demonstrated limits of agreement of -4.7% to 6.1% for ear and -3.3% to 3.4% for forehead sites.ConclusionsThe new reflectance forehead Spo(2) probe tested has acceptable agreement with the older transmittance probe placed on the earlobe for pulse oximetry within typical ranges of Spo(2) in patients undergoing vascular surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.