• J Clin Monit · Oct 1989

    Comparative Study

    Pulse oximetry and finger blood pressure measurement during open-heart surgery.

    • T S Kurki, N T Smith, T J Sanford, and N Head.
    • Department of Anesthesiology, University of California, San Diego.
    • J Clin Monit. 1989 Oct 1;5(4):221-8.

    AbstractPulse oximeter arterial hemoglobin oxygen saturation (SpO2) and finger arterial pressure (FINAP) were continuously monitored before, during, and after cardiopulmonary bypass in 15 male patients. SpO2 was monitored simultaneously with two pulse oximeters, a Nellcor N-100 and an Ohmeda Biox III. The readings obtained from the two pulse oximeters were compared with arterial blood measurements obtained using a CO-oximeter. FINAP was monitored by a prototype device (Finapres) based on the Penaz volume-clamp method. FINAP was correlated with intraarterial pressure (IAP). Both pulse oximeters functioned well before cardiopulmonary bypass. The correlations with CO-oximeter values were 0.927 for the N-100 and 0.921 for the Biox III. Immediately after the onset of cardiopulmonary bypass, the N-100 pulse oximeter stopped displaying values. The Biox III pulse oximeter continued to display values during the cardiopulmonary bypass period; the correlation with CO-oximeter values was 0.813. After cardiopulmonary bypass, the N-100 began displaying values in 2 to 10 minutes. After cardiopulmonary bypass the correlation with CO-oximeter values was 0.792 for the N-100 and 0.828 for the Biox III pulse oximeter. The Finapres finger blood pressure device functioned well in 13 of 15 patients before cardiopulmonary bypass. The mean bias +/- precision of FINAP-IAP for mean pressure was 8.3 +/- 10.2 mm Hg (SD) and the correlation coefficient was 0.814. During cardiopulmonary bypass, the Finapres device functioned well in 10 of 15 patients. The mean bias precision of FINAP-IAP, for mean pressure in these 10 patients was 6.6 +/- 8.7 mm Hg and the correlation coefficient was 0.902.(ABSTRACT TRUNCATED AT 250 WORDS)

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.