• Europace · Jan 2011

    Comparative Study

    Comparison of a non-invasive arterial pulse contour technique and echo Doppler aorta velocity-time integral on stroke volume changes in optimization of cardiac resynchronization therapy.

    • Irene E van Geldorp, Tammo Delhaas, Ben Hermans, Kevin Vernooy, Bernard Broers, Julija Klimusina, Francois Regoli, Francesco F Faletra, Tiziano Moccetti, Bart Gerritse, Richard Cornelussen, Jos J Settels, Harry J G M Crijns, Angelo Auricchio, and Frits W Prinzen.
    • Department of Physiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, PO Box 616, NL-6200 MD Maastricht, The Netherlands. i.vangeldorp@fys.unimaas.nl
    • Europace. 2011 Jan 1;13(1):87-95.

    AimsWe investigated the accuracy and feasibility of a non-invasive arterial pulse contour technique for continuous measurement of stroke volume (SV) in optimization of atrioventricular (AV) delay in cardiac resynchronization therapy (CRT), by comparing SV changes assessed by Nexfin CO-Trek® (Nexfin) and echo Doppler aortic velocity-time integral (VTIao). Furthermore, we investigated whether AV-delay optimization increases the effect of CRT when compared with a default AV delay (120 ms).Methods And ResultsIn 23 CRT patients, biventricular pacing (BiVP) was applied at various AV delays, while recording 10 beats preceding BiVP (baseline) and the first 10 BiVP beats, for both methods in parallel. Agreement between Nexfin and VTIao measurements was evaluated (Bland-Altman) on beat-to-beat changes in SV, as well as on effects of BiVP (averaged over 8 beats) at various AV delays. Individual optimal AV delays, for Nexfin (AVopt-n) and VTIao (AVopt-ao), were derived from the second-order polynomial fitted to the effect measurements of 20 patients. In 252 episodes assessed, the difference between measurements (= Nexfin - VTIao) was -0.6 ± 8.1% for beat-to-beat SV changes and -1.3 ± 7.3% for effects of BiVP. Optimal AV delays for Nexfin were well related to AVopt-ao (R(2) = 0.69). The effect (%) of BiVP at the optimal AV delay was significantly larger than at the default AV delay: median difference (range) being +6.3% (0.1-14.4%; P < 0.001) for VTIao and +4.7% (0.0-14.0%; P < 0.001) for Nexfin.ConclusionIndividual AV optimization increases the effect of CRT. Nexfin is a promising tool in individual CRT optimization, as Nexfin agrees with VTIao on measuring beat-to-beat SV changes and on assessing relative effects of BiVP on SV at various AV delays.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…