Am J Health Syst Pharm · Jul 2007
Comparative StudyAdverse events involving intravenous patient-controlled analgesia.
- Cheryl S Hankin, Jeff Schein, John A Clark, and Sunil Panchal.
- Biomedecon, LLC, Moss Beach, CA 94038, USA. cherylhankin@biomedecon.com
- Am J Health Syst Pharm. 2007 Jul 15;64(14):1492-9.
PurposeThis article systematically characterizes aspects of all Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) reports associated with i.v. patient-controlled analgesia (PCA) postoperative use during a two-year index period.MethodsIntravenous PCA represents a well-accepted and satisfactory means of acute pain treatment; case reports and large case series have described the occurrence of i.v. PCA-related adverse drug events (ADEs). MAUDE data files were downloaded, and all records pertaining to i.v. PCA devices were extracted for the two-year period from January 1, 2002, through December 31, 2003. Medical device events were categorized by their reported cause, including patient-related event, device safety event, operator error, and adverse reactions to opioids. Because there was not sufficient information to grade the certainty of each reported cause, all reported causes were graded "possible," except for device safety events that were confirmed on inspection by the manufacturer.ResultsThere were 2009 individual i.v. PCA-related MAUDE medical device events reported during the two-year period. Of these events, 1590 (79.1%) were classified as possible device safety events, 131 (6.5%) as possible operator error, 25 (1.2%) as possible adverse reactions to opioids, 12 (0.6%) as possible patient-related events, and 235 (11.7%) as indeterminate.ConclusionManufacturer-confirmed device malfunction was a major cause of reported ADE with i.v. PCA infusion pumps while operator errors were more likely to be associated with more serious adverse outcomes than device safety problems. To reduce the incidence of these problems, potential vulnerabilities in the design and manufacture of i.v. PCA pumps must be identified and addressed.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.