• J. Thorac. Cardiovasc. Surg. · Jun 2011

    Multicenter Study

    St Jude Medical Epic porcine bioprosthesis: results of the regulatory evaluation.

    • W R Eric Jamieson, Clifton T P Lewis, Marc P Sakwa, Denton A Cooley, Vibhu R Kshettry, Kent W Jones, Tirone E David, John A Sullivan, Guy J Fradet, and David S Bach.
    • University of British Columbia, Vancouver, British Columbia, Canada. eric.jamieson@vch.ca
    • J. Thorac. Cardiovasc. Surg. 2011 Jun 1;141(6):1449-54.e2.

    BackgroundThe St Jude Medical Epic heart valve (St Jude Medical, Inc, St Paul, Minn) is a tricomposite glutaraldehyde-preserved porcine bioprosthesis. The St Jude Medical Biocor porcine bioprosthesis is the precursor valve to the St Jude Medical Epic valve. The Epic valve is identical to the Biocor valve except that it is treated with Linx AC ethanol-based calcium mitigation therapy.MethodsThe St Jude Medical Epic valve was implanted in 761 patients (mean age 73.9 ± 9.2 years) between 2003 and 2006 in the US Food and Drug Administration regulatory study in 22 investigational centers. The position distribution was 557 aortic valve replacements, 175 mitral valve replacements, and 29 double valve replacements. Concomitant coronary artery bypass grafting was performed in 50.8% of patients undergoing aortic valve replacement and 36.6% of those undergoing mitral valve replacement.ResultsThe early mortality was 3.6% in aortic and 2.3% in mitral valve replacement. The follow-up was 1675.5 patient-years with a mean of 2.2 ± 1.2 years/patient. Late mortality was 5.2%/patient-year in aortic and 6.6%/patient-year in mitral valve replacement. The late major thromboembolism rate was 0.98%/patient-year for aortic and 2.6%/patient-year for mitral valve replacement. There were 19 reoperations, including 2 for structural valve deterioration, 1 for thrombosis, 9 for nonstructural dysfunction, and 7 for prosthetic valve endocarditis. The actuarial freedom from reoperation owing to structural valve deterioration for aortic valve replacement at 4 years for age 60 years or less was 93.3% ± 6.4%; for ages 61 to 70 years, 98.1% ± 1.9%; and for older than 70 years, 100% (P = .0006 > 70 vs ≤ 60 years). There were no events of structural deterioration with mitral valve replacement. The actuarial freedom from major thromboembolism for all patients at 4 years was 93.6% ± 1.0%. The 2 cases of structural valve deterioration occurred in aortic valves that became perforated without calcification causing aortic regurgitation.ConclusionsThe performance of the St Jude Medical Epic porcine bioprosthesis is satisfactory at 4 years for both aortic and mitral valve replacement. This study establishes the early clinical performance including durability of this porcine bioprosthesis.Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…