• Innovations (Phila) · Jul 2013

    Multicenter Study Comparative Study

    Two alternative sutureless strategies for aortic valve replacement: a two-center experience.

    • Giovanni Concistrè, Giuseppe Santarpino, Steffen Pfeiffer, Pierandrea Farneti, Antonio Miceli, Francesca Chiaramonti, Marco Solinas, Mattia Glauber, and Theodor Fischlein.
    • From the *Department of Cardiac Surgery - Klinikum Nürnberg, Nuremberg, Germany; and †Department of Cardiac Surgery, Ospedale del Cuore "G. Pasquinucci," Fondazione Monasterio-CNR, Massa, Italy.
    • Innovations (Phila). 2013 Jul 1;8(4):253-7.

    ObjectiveImportant comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses.MethodsWe compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy).ResultsBaseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017).ConclusionsAortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…