-
Innovations (Phila) · Jul 2013
Multicenter Study Comparative StudyTwo alternative sutureless strategies for aortic valve replacement: a two-center experience.
- Giovanni Concistrè, Giuseppe Santarpino, Steffen Pfeiffer, Pierandrea Farneti, Antonio Miceli, Francesca Chiaramonti, Marco Solinas, Mattia Glauber, and Theodor Fischlein.
- From the *Department of Cardiac Surgery - Klinikum Nürnberg, Nuremberg, Germany; and †Department of Cardiac Surgery, Ospedale del Cuore "G. Pasquinucci," Fondazione Monasterio-CNR, Massa, Italy.
- Innovations (Phila). 2013 Jul 1;8(4):253-7.
ObjectiveImportant comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses.MethodsWe compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy).ResultsBaseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017).ConclusionsAortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.