Eur J Cardiothorac Surg · Sep 2011
Multicenter Study Clinical TrialClinical experience with the ATS 3f Enable® Sutureless Bioprosthesis.
- Sven Martens, Jerzy Sadowski, Friedrich S Eckstein, Krzysztof Bartus, Boguslaw Kapelak, Hans-Hinrich Sievers, Christian Schlensak, and Thierry Carrel.
- Department for Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe University, Frankfurt, Germany. martens.herz@gmx.de
- Eur J Cardiothorac Surg. 2011 Sep 1;40(3):749-55.
ObjectiveThe ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures.MethodsA total of 140 patients (mean age: 76 ± 6 years; 63% of patients in New York Heart Association (NYHA) stage III-IV) received the ATS 3f Enable(®) Bioprosthesis in 10 European centers between March 2007 and December 2009. The total accumulated follow-up is 121.8 patient-years.ResultsValve implantation resulted in significant improvement of patients' symptoms. Mean systolic gradient was 9.04 ± 3.56 and 8.62 ± 3.16 mm Hg with mean effective orifice area of 1.69 ± 0.52 and 1.67 ± 0.44 at 6 months and 1 year, respectively. No significant transvalvular aortic regurgitation was observed. Early complications included three major paravalvular leaks (PVL; 2.1%) resulting in valve explantation and one thrombo-embolic (0.7%) event. All, but one, of the early PVLs were evident intra-operatively with the medical decision made not to reposition or resolve immediately. Late adverse events included three explantations (2.5% per patient-year): one due to PVL and two due to endocarditis. There was an additional case of late endocarditis (0.8% per patient-year) that resolved by medical management. No structural deterioration, valve-related thrombosis or hemolysis was documented.ConclusionsThe sutureless valve implantation technique is feasible and safe with the ATS 3f Enable Bioprosthesis. Valve implantation resulted in excellent hemodynamics and significant clinical improvement. Overall, these data confirm the safety and clinical utility of the Enable® Bioprosthesis for aortic valve replacement.Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.