Randomized Controlled Trial
Hands-off time during insertion of six airway devices during cardiopulmonary resuscitation: a randomised manikin trial.
- Kurt Ruetzler, Christina Gruber, Sabine Nabecker, Philipp Wohlfarth, Anita Priemayr, Michael Frass, Oliver Kimberger, Daniel I Sessler, and Bernhard Roessler.
- Department of Cardiothoracic and Vascular Anesthesia and Intensive Care Medicine, Medical University of Vienna, Vienna, Austria.
- Resuscitation. 2011 Aug 1;82(8):1060-3.
IntroductionCardiopulmonary resuscitation (CPR) guidelines recommend limiting interruptions of chest compressions because prolonged hands-off (i.e., non-compression) time compromises tissue perfusion. 2010 European Resuscitation Council guidelines suggest that chest compressions should be paused less than 10 s during airway device insertion.MethodsWith approval of the local ethics committee of the Medical University of Vienna and written informed consent, we recruited 40 voluntary emergency medical technicians, none of whom had advanced airway management experience. After a standardised audio-visual lecture and practical demonstration, technicians performed airway management with each six airway devices (endotracheal tube, Combitube, EasyTube, laryngeal tube, Laryngeal Mask Airway, and I-Gel) during on-going chest compressions in a randomised sequence on a Resusci Anne Advanced Simulator. Data were analysed using a mixed-effects model accounting for the repeated measurements and pair-wise comparisons among the airway devices.ResultsThe hands-off time associated with airway management using an endotracheal tube (including all intubation attempts) was 48 s (95% confidence interval: 43-53). The hands-off time for airway management using a laryngeal tube was 8.4 (3.4-16.4) s, Combitube 10.0 (4.9-15.1) s, EasyTube 11.4 (6.4-16.4) s, LMA 13.3 (8.2-18.3) s and for I-Gel 15.9 (10.8-20.9) s. Hands-off time was significantly longer with the conventional endotracheal tube than with any of the other airway systems. Only a third of the technicians successfully inserted an endotracheal tube whereas all of them successfully positioned each supraglottic device.ConclusionSupraglottic devices appear to be a reasonable emergency airway management strategy, even for inexperienced personnel.Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.