• J Vasc Interv Radiol · Aug 2010

    Multicenter Study Clinical Trial

    The safety and effectiveness of the retrievable option inferior vena cava filter: a United States prospective multicenter clinical study.

    • Matthew S Johnson, Albert A Nemcek, James F Benenati, Dirk S Baumann, Bart L Dolmatch, John A Kaufman, Mark J Garcia, Michael S Stecker, Anthony C Venbrux, Ziv J Haskal, and Rui L Avelar.
    • Department of Radiology, Indiana University School of Medicine, 550 University Blvd, Indianapolis, IN 46202, USA. matjohns@iupui.edu
    • J Vasc Interv Radiol. 2010 Aug 1;21(8):1173-84.

    PurposeTo evaluate the safety and effectiveness of the retrievable Option inferior vena cava (IVC) filter in patients at risk for pulmonary embolism (PE).Materials And MethodsThis was a prospective, multicenter, single-arm clinical trial. Subjects (N = 100) underwent implantation of the IVC filter and were followed for 180 days; subjects whose filters were later removed were followed for 30 days thereafter. The primary objective was to determine whether the one-sided lower limit of the 95% CI for the observed clinical success rate was at least 80%. Clinical success was defined as technical success (deployment of the filter such that it was judged suitable for mechanical protection from PE) without subsequent PE, significant filter migration or embolization, symptomatic caval thrombosis, or other complications.ResultsTechnical success was achieved in 100% of subjects. There were eight cases of recurrent PE, two cases of filter migration (23 mm), and three cases of symptomatic caval occlusion/thrombosis (one in a subject who also experienced filter migration). No filter embolization or fracture occurred. Clinical success was achieved in 88% of subjects; the one-sided lower limit of the 95% CI was 81%. Retrieval was successful at a mean of 67.1 days after implantation (range, 1-175 d) for 36 of 39 subjects (92.3%). All deaths (n = 17) and deep vein thromboses (n = 18) were judged to have resulted from preexisting or intercurrent illnesses or interventions and unrelated to the filter device; all deaths were judged to be unrelated to PE.ConclusionsPlacement and retrieval of the Option IVC filter were performed safely and with high rates of clinical success.Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.