-
J Vasc Interv Radiol · Nov 2005
Multicenter Study Clinical TrialThe Jonas study: evaluation of the retrievability of the Cordis OptEase inferior vena cava filter.
- Vincent L Oliva, Ferenc Szatmari, Marie-France Giroux, Bruce K Flemming, Sidney A Cohen, and Gilles Soulez.
- Department of Radiology, Centre Hospitalier de l'Université de Montréal, Quebec, Canada. voliva@sympatico.ca
- J Vasc Interv Radiol. 2005 Nov 1;16(11):1439-45; quiz 1445.
PurposeTo evaluate the success, safety, and efficacy of the retrieval of the OptEase Permanent/Retrievable Vena Cava Filter (Cordis, Warren, NJ), when implanted for temporary protection against venous thromboembolism.Materials And MethodsThis prospective, multicenter, non-randomized study enrolled 27 patients who needed temporary protection against pulmonary embolism in whom the intent at the time of filter insertion was retrieval of the OptEase filter. Patients presented with deep venous thrombosis (n = 17), pulmonary embolism (PE) (n = 6), and high risk for PE without thromboembolic disease (n = 4). Assessments included duplex sonography of the access site performed within 24 hours of device implantation and retrieval. All patients underwent cavography before and after filter placement and filter retrieval. Contrast-enhanced computed tomography (CT) of the abdomen and clinical follow-up was performed at 1 month after device retrieval.ResultsOf the 27 enrolled patients, 21 patients (77.8%) met the criteria for retrieval and all 21 patients (100%) had filters successfully retrieved with no associated adverse events. Retrieval was not attempted in six patients as a result of ongoing contraindication to anticoagulation (n = 3), large trapped thrombi within the filter (n = 2), and poor patient prognosis (n = 1). Time to retrieval ranged from 5 to 14 days with a mean implantation time of 11.1 days +/- 1.82. No symptomatic pulmonary embolism, vena cava wall injury, vena cava stenosis, significant bleeding, filter fracture, or filter migration was observed. Nineteen of the 21 patients (90.5%) were followed for 1-month post-retrieval with no device-related adverse events or symptomatic PE. Caval patency was documented in 18 of these 19 patients with CT. Two patients were lost to follow-up, and one patient refused to undergo CT examination.ConclusionThe OptEase permanent/retrievable vena cava filter can be safely and successfully retrieved up to 14 days in patients who no longer require inferior vena cava filter protection against pulmonary embolism.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.