• Reg Anesth Pain Med · Jul 2009

    Ultrasound-guided cervical selective nerve root block: a fluoroscopy-controlled feasibility study.

    • Samer N Narouze, Amaresh Vydyanathan, Leonardo Kapural, Daniel I Sessler, and Nagy Mekhail.
    • Pain Management Department, Cleveland Clinic Foundation, 9500 Euclid Ave C25, Cleveland, OH 44195, USA. narouzs@ccf.org
    • Reg Anesth Pain Med. 2009 Jul 1;34(4):343-8.

    Background And ObjectivesReports of intravascular injection during cervical transforaminal injections, even after confirmation by contrast fluoroscopy, have led some to question the procedure's safety. As ultrasound allows for visualization of soft tissues, nerves, and vessels, thus potentially improving precision and safety, we evaluated its feasibility in cervical nerve root injections.MethodsThis is a prospective series of 10 patients who received cervical nerve root injections using ultrasound as the primary imaging tool, with fluoroscopic confirmation. Our radiologic target point was the posterior aspect of the intervertebral foramen just anterior to the superior articular process in the oblique view and at the midsagittal plane of the articular pillars in the anteroposterior (AP) view.ResultsThe needle was exactly at the target point in 5 patients in the oblique view and in 3 patients in the AP views. The needle was within 3 mm in all patients in the lateral oblique view and in 8 patients in the AP view. In the remaining 2 patients, the needle was within 5 mm from the radiologic target. In 4 patients, we were able to identify vessels at the anterior aspect of the foramen, whereas 2 patients had critical vessels at the posterior aspect of the foramen, and in 1 patient, this artery continued medially into the foramen, most likely forming or joining a segmental feeder artery. In both cases, the vessels might well have been in the pathway of a needle correctly positioned under fluoroscopic control.ConclusionsOur case series shows the feasibility of using ultrasound imaging to guide selective cervical nerve root injections. It may facilitate identifying critical vessels at unexpected locations relative to the intervertebral foramen and avoiding injury to such vessels, which is the leading cause of the reported complications from cervical nerve root injections. A randomized controlled trial to compare the effectiveness and safety of ultrasound imaging against other imaging techniques seems warranted.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…