• Ann. Thorac. Surg. · May 2015

    Sutureless prostheses and less invasive aortic valve replacement: just an issue of clamping time?

    • Marco Vola, Salvatore Campisi, Antoine Gerbay, Jean-François Fuzellier, Iness Ayari, Jean-Pierre Favre, Michael Faure, Jerôme Morel, and Amedeo Anselmi.
    • Cardiovascular Surgery Unit, University Hospital St-Etienne, St-Priest en Jarez, France. Electronic address: marco.vola@univ-st-etienne.fr.
    • Ann. Thorac. Surg. 2015 May 1;99(5):1518-23.

    BackgroundRecently, sutureless aortic bioprostheses have been increasingly adopted to facilitate minimally invasive aortic valve replacement. We aimed at evaluating the impact of the transition from conventional bioprostheses to the routine use of the 3f Enable prosthesis (Medtronic ATS Medical, Minneapolis, MN) for aortic valve replacement through ministernotomy.MethodsBetween November 2009 and November 2012, 83 consecutive minimally invasive aortic valve replacement procedures were performed in our institution by the same surgeon through an upper T-shaped ministernotomy. The earliest 42 patients (group A) received a conventional bioprosthesis, and the later 41 patients (group B) received the sutureless 3f Enable valve. Aortic clamping and cardiopulmonary bypass times, early outcomes, and valve hemodynamics were compared.ResultsThere was no statistical intergroup difference in baseline characteristics. In-hospital mortality was 1% (a single nonvalve-related death). Average aortic clamping times in group A and group B were, respectively, 85 ± 17 and 47 ± 11 minutes (p < 0.0001); the cardiopulmonary bypass time was 108 ± 21 and 69 ± 15 minutes, respectively (p < 0.0001). There were three paravalvular leakages in group A (grade I) and four in group B (two grade I, and two grade II); three pacemaker implantations occurred in group B (p = 0.07); mean transvalvular gradient at discharge was 16.9 ± 9.1 mm Hg in group A and 11.4 ± 4.3 mm Hg in group B (p = 0.0007). During follow-up (average 25.5 ± 12.9 months), one structural valve deterioration was registered in group A, and was treated with a valve-in-valve procedure.ConclusionsIn our initial experience, the sutureless 3f Enable technology significantly reduced the clamping and cardiopulmonary bypass times, as well as the mean transvalvular gradient in aortic valve replacement through ministernotomy.Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…