• Innovations (Phila) · Jan 2013

    Sutureless aortic valve implantation through an upper v-type ministernotomy: an innovative approach in high-risk patients.

    • Giovanni Concistrè, Antonio Miceli, Francesca Chiaramonti, Pierandrea Farneti, Stefano Bevilacqua, Egidio Varone, Marco Solinas, and Mattia Glauber.
    • Department of Adult Cardiac Surgery, G. Pasquinucci Heart Hospital, Fondazione CNR-G. Monasterio, Massa, Italy. gioconci@libero.it
    • Innovations (Phila). 2013 Jan 1;8(1):23-8.

    ObjectiveAortic valve replacement in minimally invasive approach has shown to improve clinical outcomes even with a prolonged cardiopulmonary bypass and aortic cross-clamp (ACC) time. Sutureless aortic valve implantation may ideally shorten operative time. We describe our initial experience with the sutureless 3f Enable (Medtronic, Inc, ATS Medical, Minneapolis, MN USA) aortic bioprosthesis implanted in minimally invasive approach in high-risk patients.MethodsBetween May 2010 and May 2011, thirteen patients with severe aortic stenosis underwent aortic valve replacement with the 3f Enable bioprosthesis through an upper V-type ministernotomy interrupted at the second intercostal space. The mean ± SD age was 77 ± 3.9 years (range, 72-83 years), 10 patients were women, and the mean ± SD logistic EuroSCORE was 15% ± 13.5%. Echocardiography was performed preoperatively, at postoperative day 1, at discharge, and at follow-up. Clinical data, adverse events, and patient outcomes were recorded retrospectively. The median follow-up time was 4 months (interquartile range, 2-10 months).ResultsMost of the implanted valves were 21 mm in diameter (19-25 mm). The CPB and ACC times were 100.2 ± 25.3 and 66.4 ± 18.6 minutes. At short-term follow-up, the mean ± SD pressure gradient was 14 ± 4.9 mm Hg; one patient showed trivial paravalvular leakage. No patients died during hospital stay or at follow-up.ConclusionsThe 3f Enable sutureless bioprosthesis implanted in minimally invasive approach through an upper V-type ministernotomy is a feasible, safe, and reproducible procedure. Hemodynamic and clinical data are promising. This innovative approach might be considered as an alternative in high-risk patients. Reduction of CPB and ACC time is possible with increasing of experience and sutureless evolution of actual technology.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…