Eur J Cardiothorac Surg · Sep 2004
Cardiac output monitoring by pressure recording analytical method in cardiac surgery.
- Pierpaolo Giomarelli, Bonizella Biagioli, and Sabino Scolletta.
- Department of Surgery and Bioengineering, Thoracic and Cardiovascular Unit, University of Siena, Viale Bracci 1, 53100 Siena, Italy.
- Eur J Cardiothorac Surg. 2004 Sep 1;26(3):515-20.
ObjectiveA less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery.MethodsCardiac output was measured in 28 patients undergoing coronary artery bypass grafting at 15 min after anaesthesia induction, 30 min after extracorporeal circulation, 1 and 3 h after arrival in the intensive care unit using thermodilution (ThD) method through a pulmonary artery catheter and PRAM. ThD cardiac output was calculated as the mean of five separate measurements. PRAM provided beat-by-beat cardiac output data continuously throughout the study and the cardiac output values displayed on a dedicated personal computer at each time point were recorded. Correlations were calculated and differences were compared by Bland-Altman analysis.ResultsA total of 112 measurements were obtained. Cardiac output ranged from 2.3 to 7.4 l/min, and a good linear correlation (R2=0.78, P<0.0001) was found between ThD and PRAM. The highest degree of correlation (R2=0.86) was obtained at 3 h after arrival in the intensive care unit. The lower degree of correlation (R2=0.70) was obtained 30 min after extracorporeal circulation. At Bland-Altman analysis, the overall estimates of cardiac output measured by PRAM closely agreed with ThD (mean difference, 0.027; standard deviation, 0.43; limits of agreement, -0.83 and +0.89).ConclusionsUnder the studied conditions, our results demonstrate good agreement between PRAM data and ThD measurements, and this new method has shown to be accurate for real-time monitoring of cardiac output in cardiac surgery. Further studies will be required to assess this method in higher-risk patients and in the setting of haemodynamic instability or arrhythmias. This is the first study designed to assess the accuracy of PRAM in cardiac surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.